XLPE insulated LSZH sheath SWA power cable rated voltage 1KV

Brand Name:CHINT
Certification:CE/SGS/KEMA
Model Number:LSZH(WDZR-YJY23)
Minimum Order Quantity:Negotiable
Place of Origin:CHINA
Price:Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Jiaxing Zhejiang China
Address: 1#Jiangnan Road,Nanhu district ,Jiaxing city, Zhejiang province China
Supplier`s last login times: within 2 hours
Product Details Company Profile
Product Details

XLPE insulated LSZH sheath SWA power cable rated voltage 1KV


Detailed Product Description

Standards

International: IEC 60502, IEC 60228, IEC 60332, IEC 60754

China: GB∕T 12706.1-2008, GB∕T 19666-2005

Other standards such as BS,VDE and ICEA upon request


Benefits of FR Cable

When a fire occurs, the combustion of combustibles in the ordinary power system will produce a large amount of halogen-containing smoke. The LSOH power cable and the LSOH building materials used together can effectively reduce the total amount of smoke released by combustible combustion and the content of halogen, so as to reduce the casualty rate in the fire.

The cable has better axial tension resistance.


What is LSOH Power Cable

Typical structure of LSOH flame-retardant cable: non-metallic cable cladding material is LSOH flame-retardant material with different properties. This structure enables the cable to pass class A tests in IEC 60332-3-22 and related tests in IEC 60754 and IEC 61034.


Constructions

Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with BS EN 60228

Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃

Interlining: LSOH Flame Retardant Polyolefin, black

Armouring: SWA(Steel Wire Armouring)

Sheath : LSOH Flame Retardant Polyolefin, black


Note:

Insulation identification as per standards or customer requirement


Applications

Laying in room ,tunnel ,cable trench ,and pipes.


Technical data

Rated voltage: 0.6/1 kV

Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.

Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃

Min. Bending Radius: single core cable 20(d+D)±5%

Multi-core cable 15(d+D)±5%


Certificates

CE, SGS, KEMA and more others at request


Technical Specifications


Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulation
Thickness
Diameter of steel wireSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×107/1.330.70.801.812.12551.833.57794
1×167/1.670.70.801.813.13271.153.5100120
1×257/2.100.90.801.814.84470.7273.5130155
1×357/2.480.91.251.816.86030.5243.5160185
1×5010/2.561.01.251.818.07430.3873.5195220
1×7014/2.561.11.251.819.99770.2683.5245270
1×9519/2.561.11.601.822.212920.1933.5300320
1×12024/2.561.21.601.823.915610.1533.5349365
1×15030/2.561.41.601.825.718580.1243.5400410
1×18537/2.561.61.601.827.822690.09913.5465465
1×24048/2.581.71.601.930.428640.07543.5550540
1×30060/2.581.82.00233.735730.06013.5635610
1×40060/2.932.02.002.237.545300.0473.5745695
1×50060/3.332.22.002.341.355820.03663.5860780
1×63060/3.762.42.502.447.171940.02833.5990880
2×1.51/1.380.70.801.812.630012.13.52031
2×2.51/1.760.70.801.813.43437.563.52741
2×41/2.230.70.801.814.34044.613.53553
2×61/2.740.71.251.816.25813.083.54566
2×107/1.330.71.251.818.77641.833.56390
2×167/1.670.71.251.820.79581.153.584117
2×257/2.100.91.601.824.814180.7273.5113151
2×357/2.480.91.601.826.417120.5243.5139181
2×5010/2.561.01.601.923.917400.3873.5161210
2×7014/2.561.12.00227.624490.2683.5204257
2×9519/2.561.12.002.130.430820.1933.5252310
2×12024/2.561.22.002.333.036680.1533.5291351
2×15030/2.561.42.502.437.246690.1243.5333393
2×18537/2.561.62.502.640.956650.09913.5385445
2×24048/2.561.72.502.745.370470.07543.5457516
2×30060/2.561.82.502.949.484600.06013.5527583
3×1.51/1.380.70.801.813.033112.13.52031
3×2.51/1.760.70.801.813.83847.563.52741
3×41/2.230.71.251.815.85624.613.53553
3×61/2.740.71.251.816.96673.083.54566
3×107/1.330.71.251.819.68891.833.56390
3×167/1.670.71.601.822.412661.153.584117
3×257/2.100.91.601.826.117120.7273.5113151
3×357/2.480.91.601.827.821010.5243.5139181
3×5010/2.561.01.60227.523700.3873.5161210
3×7014/2.561.12.002.131.933220.2683.5204257
3×9519/2.561.12.002.235.242330.1933.5252310
3×12024/2.561.22.002.338.250660.1533.5291351
3×15030/2.561.42.502.543.764780.1243.5333393
3×18537/2.561.62.502.747.978730.09913.5385445
3×24048/2.561.72.502.953.398740.07543.5457516
3×30060/2.561.82.50357.9118990.06013.5527583
4×1.51/1.380.70.801.813.837312.13.52031
4×2.51/1.760.71.251.815.65457.563.52741
4×41/2.230.71.251.816.76414.613.53553
4×61/2.740.71.251.817.97663.083.54566
4×107/1.330.71.251.821.010391.833.56390
4×167/1.670.71.601.824.114941.153.584117
4×257/2.100.91.601.828.220530.7273.5113151
4×357/2.480.91.601.930.325660.5243.5139181
4×5010/2.561.02.002.131.331560.3873.5161210
4×7014/2.561.12.002.235.341530.2683.5204257
4×9519/2.561.12.002.339.453240.1933.5252310
4×12024/2.561.22.502.544.868710.1533.5291351
4×15030/2.561.42.502.749.182250.1243.5333393
4×18537/2.561.62.502.854.1100450.09913.5385445
4×24048/2.561.72.503.160.8127250.07543.5457516
4×30060/2.561.82.503.366.0153470.06013.5527583
5×1.51/1.380.70.801.814.641812.13.52031
5×2.51/1.760.71.251.816.56087.563.52741
5×41/2.230.71.251.817.87294.613.53553
5×61/2.740.71.251.819.28783.083.54566
5×107/1.330.71.601.823.313331.833.56390
5×167/1.670.71.601.826.017321.153.584117
5×257/2.100.91.601.930.824180.7273.5113151
5×357/2.480.92.00233.832640.5243.5139181
5×5019/1.861.02.002.234.838140.3873.5161210
5×7014/2.561.12.002.339.550530.2683.5204257
5×9519/2.561.12.502.545.869740.1933.5252310
5×12024/2.561.22.502.750.183840.1533.5291351
5×15030/2.561.42.502.855.2100950.1243.5333393
5×18537/2.561.62.50360.5123080.09913.5385445
5×24048/2.561.72.503.367.6155520.07543.5457516
5×30060/2.561.83.153.575.3197410.06013.5527583
3×2.5+1×1.51/1.760.70.801.814.44207.563.52741
3×4+1×2.51/2.230.71.251.816.46214.613.53553
3×6+1×41/2.740.71.251.817.67333.083.54566
3×10+1×67/1.330.71.251.820.29781.833.56390
3×16+1×107/1.670.71.601.823.514141.153.584117
3×25+1×167/2.100.91.601.827.219120.7273.5113151
3×35+1×167/2.480.91.601.928.822850.5243.5139181
3×50+1×2510/2.561.01.60229.927240.3873.5161210
3×70+1×3514/2.561.12.002.135.038540.2683.5204257
3×95+1×5019/2.561.12.002.339.149180.1933.5252310
3×120+1×7024/2.561.22.502.544.664400.1533.5291351
3×150+1×7030/2.561.42.502.648.274780.1243.5333393
3×185+1×9537/2.561.62.502.753.191840.09913.5385445
3×240+1×12048/2.561.72.502.959.1115110.07543.5457516
3×300+1×15060/2.561.82.503.164.4138630.06013.5527583
3×2.5+2×1.51/1.760.71.251.816.15727.563.52741
3×4+2×2.51/2.230.71.251.817.36834.613.53553
3×6+2×41/2.740.71.251.818.68213.083.54566
3×10+2×67/1.330.71.251.821.210761.833.56390
3×16+2×107/1.670.71.601.824.915721.153.584117
3×25+2×167/2.100.91.601.828.721270.7273.5113151
3×35+2×167/2.480.91.601.930.225120.5243.5139181
3×50+2×2510/2.561.02.002.132.032290.3873.5161210
3×70+2×3514/2.561.12.002.236.142250.2683.5204257
3×95+2×5019/2.561.12.002.440.254050.1933.5252310
3×120+2×7024/2.561.22.502.545.571030.1533.5291351
3×150+2×7030/2.561.42.502.750.182430.1243.5333393
3×185+2×9537/2.561.62.502.855.6102800.09913.5385445
3×240+2×12048/2.561.72.50361.5127610.07543.5457516
3×300+2×15060/2.561.82.503.267.6154450.06013.5527583
4×2.5+1×1.51/1.760.71.251.816.35857.563.52741
4×4+1×2.51/2.230.71.251.817.67024.613.53553
4×6+1×41/2.740.71.251.818.98433.083.54566
4×10+1×67/1.330.71.601.822.612671.833.56390
4×16+1×107/1.670.71.601.825.416501.153.584117
4×25+1×167/2.100.91.601.929.822780.7273.5113151
4×35+1×167/2.480.91.601.931.627720.5243.5139181
4×50+1×2510/2.561.02.002.132.434570.3873.5161210
4×70+1×3514/2.561.12.002.336.745350.2683.5204257
4×95+1×5019/2.561.12.502.542.162590.1933.5252310
4×120+1×7024/2.561.22.502.646.376150.1533.5291351
4×150+1×7030/2.561.42.502.751.390780.1243.5333393
4×185+1×9537/2.561.62.502.956.3110930.09913.5385445
4×240+1×12048/2.561.72.503.263.0140040.07543.5457516
4×300+1×15060/2.561.83.153.470.0176920.06013.5527583

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

Armored or unarmored. If armor, the armor type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement


PACKING AND SHIPPING

We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.


Product photo

China XLPE insulated LSZH sheath SWA power cable rated voltage 1KV supplier

XLPE insulated LSZH sheath SWA power cable rated voltage 1KV

Inquiry Cart 0