Double Layer Hot Oil Boiler , Instant Hot Water Oil Boiler Low Pollutant Emission

Brand Name:Yuji
Certification:ISO CE
Model Number:Gas&Oil Fired Heat Carrier Boiler
Minimum Order Quantity:1 set
Delivery Time:15 days
Place of Origin:China (Mainland)
Contact Now

Add to Cart

Active Member
Location: Xinxiang Henan China
Address: Jingye Park International Building, Xinxiang
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Product Discription

ISO standard boiler manufacture Hot Oil Boiler

The boilers of the YY (Q) W series, also known as organic boilers for heat transport, use oil and gas as fuel, heat oil As a medium, through the Heat circulating oil pump Medium liquid cycle, transfer thermal energy t o the USO of equipment t Heat, returned to the oven for heating, and then heated by the heating oven, The heat obtained Can satisfy the requirements of the boiler. The performance of the acquisition at low temperature is characterized by the acquisition at low temperature. Its heating temperature can reach 320 in liquid phase or 400 in steam phase. Heat oil boilers can be used for heating on any production line that requires uniform and stable heating, which does not allow direct heating of the Flame, and whose temperature V It would go from 250 to 380 degrees Celsius.


The heating surface of the Caldeira is compact in the structure. The heating surface is composed of internal, medium, external (or internal, external) circular coils arranged on nearby lines. The internal coils absorb most of the heat from the heating surface of the radiation, and the high temperature flow gas enters the convective heating surface. Transfer heating Nd. The combustion gas from the Caldeira output is absorbed by the heat exchanger Na End of the pot and discharged into the atmosphere through the chimney.


Product Features

1. Easy to install:

Boilers are generally divided into upper and lower parts that are convenient for transport and installation on site, significantly shortens the installation cycle, saves installation costs, and allows the boiler to be started on time.


2. Reliable action:

The heating surface of the boiler is reasonably positioned and the hot oil circulation is smooth, which ensures the timely cooling of the kilns and the safe operation of the boiler.


3. Simple maintenance:

The boiler is equipped with several controls, the maintenance staff control is convenient and clear, giving good conditions for proper work.


4. Complete combustion:

The boiler piston is high, the fuel can be completely burned, in cooperation with secondary air, can effectively remove black smoke.


5. High efficiency grate:

The boiler grate uses two -way ventilation, which brings the ash grate forward and releases it. It avoids air leakage, oil leakage and uneven ventilation, is easy to use and has many advantages over the traditional grid.


6. Ash is easy to remove:

Installation of a heat blower in the boiler's convex heat transmission zone may remove soot quickly and effectively, avoid the effects of soot accumulation on the boiler's work or reduce thermal energy and ensure stability of the boiler's load. The heat blower shall be so equipped that it does not affect the accumulation of soot in the boiler.



Technical Parameters


Main Technical parameters of YY(Q)W Series Horizontal Oil & Gas Fired Thermal Oil Boiler
ItemUnit

YY(Q)W

-1400Y(Q)

YY(Q)W

-2100Y(Q)

YY(Q)W

-3000Y(Q)

YY(Q)W

-4200Y(Q)

YY(Q)W

-6000Y(Q)

YY(Q)W

-7000Y(Q)

Thermal PowerKW140021003000420060007000
Heat Supply104Kcal/h120180250360500600
Working PressureMPa1.01.01.01.01.01.0
Rated oil output temperature300300300300300320
Rated oil return temperature280280280280280300
Thermal Efficiency/≥92%
Fuel/Natural gas, liquefied gas, city gas, light oil
Fuel ConsumptionNatural gasNM3/h163243349489692809
Liquefied gasKg/h127.7189.9269376.8535.7624.8
City gasNM3/h347.9518.7738.310361465.41706
Light oilKg/h139.3203287.3415.2571665
Gas Feed pressureNatural Gasmbar50-10050-10050-10050-100100-200100-200
City Gasmbar70-20070-20070-20070-200100-200100-200
Rated circulating oil quantityM3/h82.95125.5177.7248.8355413
Mainframe Oil VolumeM31.191.62.23.924.35.9

Note: the fuel consumption in the table is based on light oil low calorific value 42915KJ/Kg (10260Kcal/Kg), natural gas low calorific value 35588KJ/NM3 (8500Kcal/NM3) and liquefied gas low calorific value 45998KJ/Kg (11000Kcal/Kg). Calculation of low calorific value (16750KJ/NM3 (4000Kcal/NM3) of urban gas.


Shape and Interface Dimensions of YY(Q)W Series Horizontal Oil & Gas Fired Thermal Oil Boiler
ItemUnit

YY(Q)W

-1400Y(Q)

YY(Q)W

-2100Y(Q)

YY(Q)W

-3000Y(Q)

YY(Q)W

-4200Y(Q)

Transport Dimension (L*W*H)/mm4424*1950*22435170*2250*24605808*2505*28207082*2970*3140
Mainframe transport weight/t6.28.71118
Outlet DiameterDNmm125125150200
Return Pipe DiameterDNmm125125150200
Drain Valve Pipe DiameterDNmm25///
Discharge Pipe DiameterDNmm25404040
Chimney Diameterφmm350400500600

Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.



China Double Layer Hot Oil Boiler , Instant Hot Water Oil Boiler Low Pollutant Emission supplier

Double Layer Hot Oil Boiler , Instant Hot Water Oil Boiler Low Pollutant Emission

Inquiry Cart 0