Add to Cart
Product Discription
LDR Series Vertical Electric Steam Generator
Single drum design, layout electrical heated tubes in drum, connect water level electrode control outside, the shell use thermal insulation material and color plate package. Users only need connect machine to the electricity supply and water source to use it. Steam generator set reliable water level control and pressure control devices. The cartridge heaters set at the bottom of steam generator, and it can make full use of electric energy, environmental protection and energy saving, compact and reasonable structure.
According to TSG G0001-2012<Boiler Safety Technical Supervision Regulations>1.3 clause (1) the definition of can't be called boiler, the design water level or water capacity of steam generator less than 30 L, not belong to the category of <Boiler and Pressure Vessel Manufacture supervision and management measures> stated product safety performance compulsory supervision inspection, so it can exempted from inspection of local supervisory department.
Product Features
1. Reasonable design: The steam generator body adopts vertical tubular structure, and the upper and lower Tube sheets of the body are welded with two coils of water pipe bundles.The utility model and a shell cylinder form a flue gas three-return journey together. With long flue gas heat transfer process, sufficient heating area and reasonable Structural layout. The burner is arranged on the top of the body, and the flame can be fully expanded and fully burned.
2. High efficiency and energy saving: the thermal efficiency of steam generator can reach more than 92%, and the efficiency of steam generator can reach more than 96% if it is equipped with condenser.
3. Manufacturing Specification: Each component of steam generator is manufactured in accordance with national and international standards (ISO).All production links strictly follow strict production process to ensure reliable product quality.
4.Steam drying: Steam generator has built-in steam-water separator, which can provide high quality drying steam. Because of dry steaming. Steam helps eliminate unnecessary extra condensation, thereby saving fuel, reducing system scaling and prolonging service life.
5. Reliable and durable: Excellent professional design of steam generator, excellent production process, strict quality control, is every one.Quality assurance of steam generator in Yuji.
6. High safety: It is no need for inspection, steam generator water volume less than 30Kg, high safety. No installation notice is required.
Technical Paramrters
LDR Series Steam Generator Main Technical Parameters
Unit Item | LDR0.008 | LDR0.012 | LDR0.018 | LDR0.024 | LDR0.032 | LDR0.05 | |
Rated evaporation | kg/h | 8 | 12 | 16 | 24 | 32 | 50 |
Rated Electric Power | Kw | 6 | 9 | 12 | 18 | 24 | 36 |
Rated Voltage | V | 380 | 380 | 380 | 380 | 380 | 380 |
Pump power | KW | 0.35 | 0.35 | 0.35 | 0.35 | 0.35 | 0.55 |
Section Standard for Power Supply Distribution | mm2 | 4 | 6 | 6 | 10 | 16 | 16 |
Rated Pressure | Mpa | 0.4-0.7 | |||||
Rated Steam Temperature | ℃ | 151/170 | |||||
Rated Feed Water Temperature | ℃ | 20 | |||||
Steam Generator Efficiency | / | 99% | |||||
Water volume | L | <30L | |||||
Unit Item | LDR0.065 | LDR0.075 | LDR0.1 | LDR0.115 | LDR0.13 | LDR0.2 | |
Rated evaporation | kg/h | 65 | 75 | 100 | 115 | 130 | 200 |
Rated Electric Power | Kw | 48 | 54 | 72 | 81 | 90 | 144 |
Rated Voltage | V | 380 | 380 | 380 | 380 | 380 | 380 |
Pump power | KW | 0.55 | 0.55 | 0.55 | 0.55 | 0.55 | 0.55 |
Section Standard for Power Supply Distribution | mm2 | 25 | 25 | 35 | 50 | 50 | 50 |
Rated Pressure | Mpa | 0.4-0.7 | |||||
Rated Steam Temperature | ℃ | 151/170 | |||||
Rated Feed Water Temperature | ℃ | 20 | |||||
Steam Generator Efficiency | / | 99% | |||||
Water volume | L | <30L |