High Hardness Carbide Burs Dental With Tungsten And Stainless Steel Material
10 pieces per pack Stainless Steel Rotary use Tungsten Carbide Bur RA type US NO
Specifications:
GIG NO. | 31R | 1558 |
21R | 1158 | |
23 | 0 | |
Recommended speed | 200 000 | |
Material | Head | Tungsten |
Handle | Stainless Steel |
Description:
1. Head : carbide material cutting edge is good to open tooth crown
and polish .
2. Special process : specially designed, if broken, broken parts is
closed to handle , which is easy to
remove from the root canal .
3. Handle : we have different sizes for fit with difference tooth ,
used for open crown with durable quality and double quality than
diamond burs
4. Recommended Rotary Speed : 200 000 rmp
Warning:
1. Only a skilled dentist can use it.
2. Make sure to disinfect each time you use this product.
3. Do not use this product except for dental services and
treatments. Use it as intended.
Storages and duration of use
1. Do not store under high temperature, humidity and direct sunlight. Keep the liquid away. Keep it at room temperature.
2. Do not damage or puncture the packaging materials.
3. Do not hold a germicidal lamp to prevent deterioration.
Precautions for use
1. Use only by the dentist.
2. After use, please take appropriate precautions as medical waste.
3. Discard if the product is damaged or dirty.
4. After use, wash with a medical cleaner and brush, and rinse the
foreign substances such as sticky body fluids and body tissues.
5. When cleaning with ultrasonic cleaner, please install on stand
to prevent breakdown of workpiece.
6. Be careful not to pierce your finger as this product has a sharp
piece.
Maintenances and inspections
1. Sterilize this product using the method specified in the
autoclave and
Short term for every use.
Sterilization method:
Put this product in sterilization package or foil and for autoclave
sterilization of sterilization tray or files
the following terms refer to the atifft.
Conditions for sterilization:
term (1) temperature: 121degree Celsius time: 20 minutes or more
term (2) temperature: 126degree Celsius time: 15 minutes or more
2. Do not use a high pressure steam sterilizer that is over 200
heated degrees Celsius, including the drying process.
3. When using the appliance again, completely and sterilize.
4. Follow instructions for use of medical cleaner. manually by the
manufacturer.
5. Discard damaged or degraded product
Packages
RA 22.5 mm: blister 10 pcs. single sizes
2000 Packings per cartoon: 48cm*40cm*35cm
Applications:
Dental Root Canal Treatment | Hospital , Clinic , lab... |
Competitive Advantage:
Imported raw material tungsten to make sure quality are the best
TÜV-certified Quality Management