Atomic Absorption Spectrophotometer Double Beam Laboratory Atomic Absorption Spectrophotometer AAS

Brand Name:BAXIT
Model Number:BXT-AAS8HS-P
Minimum Order Quantity:1
Delivery Time:3-5working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Place of Origin:china
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: No.5616th, Caoan Road, Jiading District, Shanghai
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

Atomic Absorption Spectrophotometer

Atomic absorption spectrophotometer can be widely applied in various industries such

as geology, metallurgy, medicine, chemical engineering, petroleum, agriculture, environmental

protection and commodity inspection. The application of it for the analysis of trace and ultra-trace

elements has gradually shifted from inorganic chemistry to organic chemistry in recent years.


Working principle

The characteristic spectral radiation of the element to be measured is emitted by the light

source and absorbed by the ground-state atoms of the element to be measured in the vapor

of the sample produced by the atomizer such as a flame or graphite furnace. The content of

the element to be measured is determined by measuring the amount of the characteristic

spectral radiation absorbed.


ClassificationFlame type
(4,6,8Lamp Positions)
Flame Graphite Integrated Machine
(4,6Lamp Positions)
Fully automatic flame graphite integrated machine
(8Lamp Positions)
ModelBXT-AAS4H
BXT-AAS6H
BXT-AAS8H
BXT-AAS4HS
BXT-AAS6HS
BXT-AAS8HS-P
DetectorHamamatsu Photomultiplier Tube from Japan
wavelength range(190-900)nm(185-900)nm
Wavelength indication error≤±0.1nm
Wavelength repeatability≤±0.025nm
Baseline drift0.001ABS/30min(Static) 0.003ABS/15min(Dynamic)
Light source systemRotary turret-type fully automatic switching lamp holder
Element lamp
Lighting mode
400Hz, 1/4 duty cycle pulse is on
MonochromatorCzerny-Turner Enhanced type
Grating line density1800
Spectral bandwidth0nm,0.1nm,0.2nm,0.4nm,1.0nm,2.0nm Multi-gear automatic switching
AtomizerFlame atomizer
Flame atomization systemStandard equipment
Burner0.5mmx100mmAll-titanium combustion head
SprayerMetal sleeve high-efficiency glass spray nozzle
Atomization chamberCorrosion-resistant all-plastic atomization chamber
RepetitionRSD≤0.7%
Detection limit(Cu)<0.006ug/ml
Safety protectionIt has multiple safety protection functions, including alarm for acetylene leakage and system shutdown.
Graphite Furnace Atomic Absorption SystemNoStandard configuration
Detection limitNo1.5pg
PrecisionNo≤3%
Heating temperature rangeNoRoom temperature-3000℃
Heating speedNo2000 degrees per second
Temperature control accuracyNo1%
Heating conditions settingNo11 step, ramp temperature rise, stepwise temperature rise, maximum power temperature rise, temperature rise monitoring opposite-side system
Safety protectionNoPressure system failure protection, cooling system failure protection, real-time power monitoring
Background correction (deuterium lamp)NoWhen using 1ABS, the value should be ≥ 60 times.
Background correctionNoWhen using 1ABS, the value should be ≥ 60 times.
Automatic sample introduction systemNo85 channels, automatic calibration curve configuration, automatic dilution function, high-precision injection
Sample size1-99
Result outputMulti-format data storage and print output
Communication interfaceRS232, USB expansion interface
Host machine size1000x400x470mm1030x430x400mm
Weight(kg)75120130