PD Free High Voltage Tester Systems , Partial Discharge Measurement Equipment

Brand Name:Fanke High-Voltage
Certification:ISO9001
Model Number:CQSB-300KVA/600KV
Minimum Order Quantity:One unit
Delivery Time:45~75 work days
Payment Terms:L/C , T/T
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

PD Free AC Withstand Voltage Test Systems With Cylinder Type Transformer , Partial Discharge Measurement


I. Products Description and Application :


PD Free AC Withstand Voltage Test Systems With Cylinder Type Transformer is used to test high voltage electrical products and components in the HV test hall, such as HV cables, power transformers, gas-insulated switchgears, bushings, arresters and insulation materials.


With wide application scope, it usually can be applied in routine test test of High voltage product quality inspection,which includes power frequency AC withstand voltage test, PD detection and cable long duration test.These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers). The voltage divider of the system has coupling terminal of PD signal , through equipped with 2 or 4 channels PD analyzer (optional), PD detecting for test object can be realized.


The model CQSB-300KVA/600KV has two stackable cylinder type Test Transformer in series connection to output 600KV test voltage and 0.5A test current. The duty cycle is 60mints on ,60mints off ,


Until now , this test set had formed many different serialized model according to different votage withstand test applications .The alike model can see other typical model at the following clause.


II. Main Components:


SNName of ComponentsType and specificationQty.Each weightEach Dimension
1Control consoleFKGB-300KVA1piece180kgs1200*420*820mm
2Electric voltage regulator cabinetDT-300KVA1piece2500kgs1100*1050*1250mm
3.1First stackable cylinder type Test TransformerCQSB-600KVA/300KV1piece3000kgsD1200*H2800mm
3.2Second stackable cylinder type Test TransformerCQSB-300KVA/300KV1piece2400kgsD1200*H2500mm
4Protection resistanceBHR-0.5A/600KV1pieces120kgsD380*L850mm
5Voltage divider with coupling capacitanceTJF-600KV/500pF1set200kgsD320*H6000mm
6Special test accessories
Note : Special requirement can be made by order.

III. Test connection figure (For example: model CQSB-500KVA/500KV):



IV. Technology Feature

  1. Pure power frequency test at 50Hz or 60Hz, output voltage distortion (THD) is very small.
  2. Meet low partial discharge measurement requirements
  3. Modular structure for saving space in the test hall
  4. Low impedance, wide application range
  5. Easy to operate with computer controlled measurement system
  6. Complete protection circuit to ensure the safety of personnel and equipment
  7. Surge and transient protection sensitive electronic components
  8. Particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers).

V. General Technical data:

  1. Mode of system test: PD Free AC Withstand Voltage Test Systems With Cylinder Type Transformer
  2. System model : CQSB-300KVA/600KV
  3. Input power supply : 380±10%(single-phase),50Hz/60Hz
  4. Rated output capacity: 300kVA
  5. Rated output Voltage: 300KV,600KV
  6. Max Test voltage : no more than 600KV
  7. Rated output current: 0.5A
  8. Reg. Freq range : 50/60Hz
  9. Output Resonance voltage waveform: pure sine wave
  10. Temperature rise: Less than 65K under rated current working 60mints;
  11. Noise level: No more than 65dB
  12. Structure: oil-immersed with cylinder type designed


VI. Other optional components

  1. Power supply noise filter
  2. Triple and fifth filter
  3. Compensating reactor
  4. Over-voltage electronic fast protection device
  5. SF6 standard capacitor·
  6. Partial discharge detector


VII. Other Typical Model


1.Single transformer type :


MODEL

Rated capacity

(KVA)

LV input supply(KV)Rated output voltage(KV)

Cylinder transformer dimension

D× H(mm)

Weight (kg)
CQSB-1.5KVA/50KV1.50.2250φ430*58065
CQSB-2.5KVA/50KV2.50.2250φ280*50070
CQSB-3KVA/50KV30.2250φ300*51072
CQSB-5KVA/50KV50.2250φ460*580110
CQSB-5KVA/100KV50.22100φ640*820130
CQSB-10KVA/100KV100.22100φ620*850160
CQSB-50KVA/100KV500.4100φ725*1100500
CQSB-12KVA/120KV120.38120φ750*1230380
CQSB-15KVA/150KV150.38150φ820*1220500
CQSB-20KVA/200KV200.38200φ1080*1700900
CQSB-50KVA/250KV500.38250φ1460*15201250
CQSB-75KVA/250KV750.38250φ1460*17801450
CQSB-75KVA/500KV750.38500φ2000*48506800
CQSB-100KVA/100KV1000.38100φ1000*1250800
CQSB-100KVA/150KV1000.38150φ1410*16201700
CQSB-100KVA/250KV1000.6250φ1100*14501550
CQSB-125KVA/250KV1250.38250φ1540*20603460
CQSB-150KVA/150KV1500.6150φ1420*16202200
CQSB-2000KVA/500KV20003500φ3000*480050000

2.Stackable cylinder transformers type:


MODEL

Rated capacity

(KVA)

LV input supply(KV)Rated output voltage(KV)

Cylinder transformer dimension

D× H(mm)

Weight (kg)
CQSB-10KVA/2*50KV100.2100φ410*980200
CQSB-25KVA/2*125KV250.38250φ1250*2200890
CQSB-100KVA/2*200KV1000.38400φ1580*36502500
CQSB-150KVA/2*150KV1500.38300φ1600*32003980
CQSB-300KVA/2*150KV3000.38300φ1600*38004280
CQSB-250KVA/2*250KV2500.38500φ2220*610011200
CQSB-500KVA/2*250KV5000.6500φ2030*460018500
CQSB-600KVA/2*300KV6003600φ3200*800019000
CQSB-1200KVA/2*300KV12000.6600φ3000*620028900
CQSB-1250KVA/2*125KV12503250φ4500*320014500
CQSB-300KVA/2*300KV3003600φ2610*560010000

China PD Free High Voltage Tester Systems , Partial Discharge Measurement Equipment supplier

PD Free High Voltage Tester Systems , Partial Discharge Measurement Equipment

Inquiry Cart 0