Portable High Voltage Cable Testing Equipment For MV Cable Testing Light Weight

Brand Name:Fanke High-voltage
Certification:ISO9001
Model Number:FKTF series
Minimum Order Quantity:One unit
Delivery Time:25-30 Work Days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Portable Variable Frequency Resonant Withstand Voltage Test Set , For MV Cable and Power Substation Test


I. Product Usage :


FKTF portable variable-frequency series resonance test device mainly aims at AC voltage test for electric equipment and electric systems below 110kv. The reactors and excitation transformers employs dry-type epoxy resin filling, small size and light weight convenient for field moving, series or parallel composition is available, which can meet the test requirements not only of transformer, GIS,breaker, mutual inductor and bushing but also that of cable below 110kv


II. Applicable objects

  • XLPE cable of 10kv,35kv,110kv
  • GIS,breaker, mutual inductor ,transformer below 110kv
  • Small and medium size of generators and motor

III. Main components

  • Variable-frequency power source
  • excitation transformer,
  • Fixed inductance reactors,
  • Capacitance voltage divider
IV. Key features
  • Portable design, less than 50kg for each components, convenient for field voltage withstand test
  • Modular structure employed by reactor, convenient and flexible
  • Test frequency: 30 ~ 300Hz
  • The output waveform is sine wave, wave form deviation factor ≤ 1%
  • Easing for wiring and operating
  • High degree of test automation, intelligent variable-frequency power source, good stability, complete protection function
  • Data inquiry function. Past test data can be inquired

VI. General Technical Data

  1. Rated capacity: OEM;
  2. Input power: three-phase 380V voltage, frequency is 50Hz;
  3. Rated voltage: 18KV, 27kV, 54kV, 50KV, 80KV, 100KV each for made by order
  4. Rated current: OEM;
  5. Working frequency: 30-300Hz;
  6. Device output waveform: sine wave
  7. Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
  8. Working time: continuous 60min allowed under rated load; overpressure 1.1 times 1 minute;
  9. Temperature rise: temperature rise ≤65K after continuous operation for 60 minutes under rated load;
  10. Quality factor: device itself Q≥30 (f=45Hz);
  11. Protection function: Over-current, over-voltage and test product flashover protection for the tested product (see the variable frequency power supply section for details);
  12. Measurement accuracy: system effective value 1.5;

V. Main Components:(FKTF-108KVA/27KV, 54KV, 108KV test set for example)


SNName of ComponentsType and specificationQty.Each weightEach Dimension
1Variable frequency powerFKVF-5kW/380V1piece35kgs450*450*500mm
2Excitation transformerCQSB(J)-5kVA/1.25KV,5KV1piece35kgs450*350*450mm
3HV resonant test reactorCHX(kf)-27kVA/27kV4pieces42kgsD350*H400mm
4Capacitive dividerTRF-110kV/1000pF1set10kgsD150*H850mm
5Special test accessories1set

VI. Test priciple connection :


VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


VII. Main Measuring and control software panel:

Note: This is the software panel before start test for parameter setting



VIII.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • Output cables of exciting transformer
  • System grounding cables
  • Parallel cables of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .


IX. Other Optional Model


1. For GIS on-site test

ModelRated voltageRated output currentRated output capacity

Application

(From 45Hz starting)

CHX-135KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
CHX-270KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
CHX-216KVA/216KV27KV*81A216KVAFor 123KV and below GIS
CHX-270KVA/270KV27KV*101A270KVAFor 145KV and below GIS
CHX-275KVA/275KV275KV2A275KVAFor 170KV and below GIS
Special requirement can be made by order

2. For 45KV XLPE cable on-site test

ModelRated voltageRated output currentRated output capacityMax Application
CHX-108/5454KV2A108KVA45kV cable≤1km
CHX-216/5454KV4A216KVA45kV cable≤2km
CHX-324/5454KV6A324KVA45kV cable≤3km
CHX-432/5454KV8A432KVA45kV cable≤4km
CHX-540/5454KV10A540KVA45kV cable≤5km
CHX-1080/5454KV20A1080KVA45kV cable≤10km
Special requirement can be made by order

3. For 66KV XLPE cable on-site test

ModelRated voltageRated output currentRated output capacityMax Application
CHX-160/8080KV2A160KVA66kV cable≤0.5km
CHX-320/8080KV4A320KVA66kV cable≤1km
CHX-640/8080KV8A640KVA66kV cable≤2km
CHX-960/8080KV12A960KVA66kV cable≤3km
CHX-1280/8080KV16A1280KVA66kV cable≤4km
CHX-1600/8080KV20A1600KVA66kV cable≤5km
CHX-3200/8080KV40A3200KVA66kV cable≤10km
CHX-9600/8080KV120A9600KVA66kV cable≤20km
Special requirement can be made by order

X. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

China Portable High Voltage Cable Testing Equipment For MV Cable Testing Light Weight supplier