Variable Frequency Resonant Withstand Voltage Test Set For Long HV XLPE Cable


I.Application :


This test set model CHX-9000KVA/150KV,300KV,450KV is designed for 132kV~400KV class long XLPE cable on-site AC hpot test and 362KV and below class GIS on-site AC hipot test with variable frequency resonant circuit technology; the highest test voltage is no more than 150KV,300KV,450KV through cylinder test reactor in parallel or in series connection ;the test frequency can be from 20-300Hz; the duty cycle is no more than 60mints.


Through modular test reactor is used in parallel or in seires, the test set model CHX-9000KVA/150KV,300KV,450KV also can be performed the following on-site AC hipot test:

1.1 No more than 150KV and 60A for long distance XLPE cable with no more than U0=87KV

1.2 No more than 300KV and 40A for long distance XLPE cable with no more than U0=160KV ;

170KV and below class GIS

1.3 No more than 450KV and 20A for long distance XLPE cable with no more than U0=230KV ;

362KV and below class GIS


Until now , these designed test set can form many different serialized model according to different HV or UHV withstand test applications through test reactors in series or in parallel connection and number of configurations in each set, The alike model can see clause 9.other typical model.


II. Main Components


SNName of ComponentsType and specificationQty.Each weightEach Dimension
1Variable frequency power supplyFKVF-300kW/380V1piece280kgs750*700*1200mm
2Excitation transformerCQSB(J)-300kVA1piece3000kgs950*850*900mm
3HV resonant test reactorCHX(kf)-3000kVA/150kV3pieces4500kgsD1200*H1250mm
4Capacitive dividerTRF-450kV/1000pF1set275kgsD250*H2850mm
5Special test accessories1set

Note:1.Load capacitantor can be optional when small load line is tesing or need analog load to control test frequency.

2.Test reactor can be produced to be 130KV,150KV,155KV,200KV, 250KV, 300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~5A,10A,15A,20A,25A,30A.

III. Test priciple figure:


VF: Variable Frequency Power Supply Source which is control and measurement part in the test circuit.

T : Excitation Transformer which provide the exciting voltage for HV test reactor
L : Test Reactor which is resonant inductance in the LC circuit and produce the test voltage

Cx: Tested Equipment

MOA1: Lightning Arrestor is protection part on the excitation transformer
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm ) which is HV voltage measurement part


IV. General Technical data:

  1. Mode of system test: Series resonant with variable frequency
  2. System model : CHX-9000KVA/150KV,300KV,450KV
  3. Input power supply : 380±10%(three-phase),50Hz/60Hz
  4. Number of HV test reactor: 3pieces
  5. Rated output capacity: 9000kVA
  6. Rated output Voltage: 150KV,300KV,450KV
  7. Max Test voltage : no more than 150KV,300KV,450KV
  8. Rated output current: 20A /single piece or in series;60A in parallal
  9. Reg. Freq range : 20Hz-300Hz
  10. Output Resonance voltage waveform: sine wave
  11. THD of output waveform: ≤1%
  12. Insulation level: Under 1.1 times and keeping 1min, normal
  13. Duty cycle : 60mins on under rated current working condition ;
  14. Quality factor of test set itself: Q≥60
  15. Temperature rise: Less than 65K under rated current working 60mints;
  16. Noise level: No more than 70B
  17. Reactor Structure: oil immersed type, epoxy tube cylinder type;


V. Main Measuring and control software panel as following :



Note: This figure is display panel at setting test parameter step from control and measurement software on the VF power supply


VI.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • Output cables of exciting transformer
  • System grounding cables
  • Parallel cables of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • Supporting base for divider
  • Corona ring for test reactor and divider
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .


VII. Other typical model


1 Optional model for 132KV class XLPE cable on-site withstand voltage test


ModelRated voltageRated output currentRated output capacityMax Application
CHX-775KVA/155KV155KV5A775KVA132kV cable≤1km
CHX-1550KVA/155KV155KV10A1550KVA132kV cable≤2km
CHX-2325KVA/155KV155KV15A2325KVA132kV cable≤3km
CHX-3100KVA/155KV155KV20A3100KVA132kV cable≤4km
CHX-3875KVA/155KV155KV25A3875KVA132kV cable≤5km
CHX-7750KVA/155KV155KV50A7750KVA132kV cable≤10km
CHX-12400KVA/155KV155KV80A12400KVA132kV cable≤16km
CHX-15500KVA/155KV155KV100A15500KVA132kV cable≤20km
Special requirement can be made by order

Note :Tested cable voltage class≤ 132kV, 0.25uF/km


2 Optional model for 230KV class XLPE cable on-site withstand voltage test


ModelRated voltageRated output currentRated output capacityMax Application
CHX-2020KVA/255KV255KV8A2020KVA220~230kV cable≤1km
CHX-4080KVA/255KV255KV16A4080KVA220~230kV cable≤2km
CHX-6120KVA/255KV255KV24A6120KVA220~230kV cable≤3km
CHX--8160KVA/255KV255KV32A8160KVA220~230kV cable≤4km
CHX--10200KVA/255KV255KV40A10200KVA220~230kV cable≤5km
CHX--20400KVA/255KV255KV80A20400KVA220~230kV cable≤10km
CHX--25500KVA/255KV255KV100A25500KVA220~275kV cable≤12.5km
Special requirement can be made by order

Note :Tested cable voltage class≤ 230kV, 0.25uF/km


3 Optional model for 330KV class XLPE cable on-site withstand voltage test


ModelRated voltageRated output currentRated output capacityMax Application
CHX-3500KVA/350KV350KV10A3500KVA330kV cable≤1km
CHX-7000KVA/350KV350KV20A7000KVA330kV cable≤2km
CHX-10500KVA/350KV350KV30A10500KVA330kV cable≤3km
CHX-14000KVA/350KV350KV40A14000KVA330kV cable≤4km
CHX-21000KVA/350KV350KV60A21000KVA330kV cable≤5km
CHX-28000KVA/350KV350KV80A28000KVA330kV cable≤10km
Special requirement can be made by order

Note :Tested cable voltage class≤ 330kV, 0.25uF/km


4 Optional other model for long XLPE cable on-site withstand voltage test


ModelRated voltageRated output currentRated output capacity

Application

(From 20Hz starting)

CHX-2600KVA/130KV130KV10A,20A1300KVAFor U0=64KV and below cable
CHX-3000KVA/150KV150KV10A, 20A3000KVAFor U0=87KV and below cable
CHX-10000KVA/250KV250KV20A, 40A10000KVAFor U0=127KV and below cable
CHX-20000KVA/250KV250KV20A, 80A20000KVAFor U0=127KV and below cable
CHX-21000KVA/350KV350KV20A, 60A21000KVAFor U0=230KV and below cable
CHX-42000KVA/350KV350KV20A, 80A42000KVAFor U0=230KV and below cable
Special requirement can be made by order

Note : XLPE cable test voltage is considering as 1.7U0


5 Optional model for HV or EHV class cable and GIS On-site AC hipot test


ModelRated voltageRated output currentRated output capacity

Application

(From 20Hz starting)

CHX-2600KVA/130KV,260KV130KV,260KV20A@130KV2600KVA

For U0=64KV cable

For 72.5KV class GIS

10A@260KV

For U0=127KV cable

For 145KV class GIS

CHX-9000KVA/150KV,300KV150KV,300KV60A@150KV9000KVA

For U0=87KV cable

For 72.5KV class GIS

30A@300KV

For U0=160KV cable

For 170KV class GIS

CHX-10000KVA/250KV,500KV250KV,500KV40A@250KV10000KVA

For U0=127KV cable

For 145KV class GIS

20A@500KV

For U0=290KV cable

For 362KV class GIS

CHX-20000KVA/250KV,500KV250KV,500KV80A@250KV20000KVA

For U0=127KV cable

For 145KV class GIS

40A@500KV

For U0=290KV cable

For 362KV class GIS

CHX-21000KVA/350KV,700KV350KV,700KV60A@350KV21000KVA

For U0=190KV cable

For 170KV class GIS

30A@700KV

For U0=290KV cable

For 550KV class GIS

Special requirement can be made by order

VIII. On-site test standard table from IEC 60840:2011 and IEC 62067:2011 for XLPE cable



IX. On-site insulation test standard table from IEC 62271-203:2011 for HV GIS