Automatic Insulation Oil Dielectric Loss Tester , Insulation Oil Volume Resistivity Tester


I. Products Description


Model FKYJS Automatic Insulation Oil Dielectric Loss Tester is a high-precision instruments used for insulating oil liquid medium dielectric loss angle and the volume resistivity. With integrated structure. Dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitors, impedance meter, and DC high voltage source are integrated within it as its major components. Its heating part adopts the most advanced high-frequency current induction heating, and which has the features such as uniform heating, fast, and easy control. Internal standard capacitor is the SF6 inflatable three-pole capacitor, which is immune from the ambient temperature, humidity, etc to guarantee precision instrument remains the same after prolonged use.

All-digital technology inside the device, all intelligent automation measurement, with a large screen (240 × 180) LCD display, full Chinese menu, each step has prompted the Chinese, the test results can be printed, the operator will be able to use it without professional training.


II. Technical Parameters


Using condition-5℃∽40℃ RH<80%Relative inductivityεr auto calculating
PowerAC220V±10%Volume resistivityρ auto calculating
HV output

1000V∽2200V

Accuracy 2%

Capacitance 50VA

Current output 25mA

Test object Range

tgδ

C x 15PF-300PF

Rx 10M-10T

Induction furnaceMax. power 500WDimension450(L)×310(W)×360(H)
Range<100℃Weight18Kg
Measuring error±0.5℃HourIf T up to 90℃ less than 20min
Error±1℃Accuracy

tg±(indication*1.0%+0.020%)

δ:±(indication *1.0%+0.5PF)

Cx :±indication * 10%


III. Configuration:

  • Host machine(1set)
  • Dielectric loss oil cup(1set)
  • Testing cable(1 piece)
  • AC220V power line(1 piece)
  • Instruction manual(1 copy)
  • Certificate of quality(1copy)
  • Protective tube,printing paper (for spare)