Add to Cart
Underground Cable Route and Cable Fault Distance Locator,
Distribution Cable Fault Detector
I. Application :
FKDL2000 cable fault distance locator is a kind of Integrated
testing apparatus , which is made from the fault detecting test
host, cable path tracing signal generator, cable tracing path
signal receiver and cable fault locator, etc.The host machine,
including the integrated computer, the low-voltage pulse generator,
and the data processor, is used to test fault distance and measure
cable length and wave propagation velocity in cable.The sine wave signal with frequency of 30KHz and amplitude peak of
30V produced by path signal generator is used to find the cable
path.Path signal receiver is used for receiving the signal path,
and used to find the cable louding and estimate the cable burial
depth. Fault locator is used for fault exact positioning.The detecting way of the has three kinds of LV impulse method, impulse HV flash-over method, multiple pulse
method. The optional part is DC high voltage booster and control
cabinet , which is used for providing a breakdown voltage to
enlarge the insulation damaged and easily repairing .
The Integrated testing apparatus is able to test cable fault at different voltage levels below 35KV.
It can test cable fault of different cable sections, different
dielectric and different cable materials. Can test open-circuit
cable fault, short-circuit cable fault, low-resistance cable fault,
high-resistance leakage cable fault and high-resistance flash-over
cable fault.
II. Technical index:
1, Fault measuring system
2, Cable Tracing Path signal generator Part
3, Cable Fault Locator Part
4. Other Technical Data
Model | FKDL2000 |
Application | Can test cable fault at different voltage levels below 35KV. Can test cable fault of different cable sections, different dielectric and different cable materials. Can test open-circuit cable fault, short-circuit cable fault, low-resistance cable fault, high-resistance leakage cable fault and high-resistance flash-over cable fault. |
Cables | Can test all faults of railway communication control cable,
streetlight cable and airport signal cable. |
Display mode | 12.1in industrial LCD touch screen (Windows XP platform) |
Test method | LV impulse method, impulse HV flash-over method, multiple pulse method |
Storage | 8G |
Test distance | no less than 60Km |
Operate | Touch pen and mouse |
Min. test distance (non-detection area): | 0-5m or without |
Locating error | ±0.2m |
Test error | system error is no ore than ±1% |
Multiple pulse generator | Impulse voltage ≤40KV |
Resolution | V/fm,V is transmitting velocity m/μs |
software cursor | 0.10m. |
Sampling frequency | 6.25MHz,12.5MHz,25MHz,50MHz,100MHz (Adaptive pulse width). |
Power source and power consumption | AC 220V±10%, power consumption≤15W |
Standby time | continuous working 6 hours |
Host weight | 6.2KG |
Dimension: | 180mm×300mm×400mm |
Temperature | -20℃- 40℃ |
Relative humidity | ≤80% |