Add to Cart
Condensed Aerosol Generators For Fire Extinguishing For Class ABCE Fires
Product Features For Condensed Aerosol Generators
1. The fire extinguishing device can extinguish class A, class B,
class C and class E fires rapidly.
Class A Fires--fires in ordinary combustible materials, such as
wood, cloth, paper, rubber, and many plastics.
Class B Fires--fires in flammable liquids, combustible liquids,
petroleum,greases, tars, oils, oil-based paints, methanol,
alcohols, etc.
Class C Fires--flammable gases fires
Class E Fires-- fires that involve energized electrical equipment.
2. The device has high fire extinguishing efficiency and high
speed. Through experimental analysis, the fire extinguishing device
can quickly reduce the temperature of the fire field, suppress the
combustion reaction, and achieve the purpose of rapid fire
extinguishing.
3. 360 degree annular nozzles, total flooding fire-extinguishing
type and extinguish fires in all direction and with zero
obstruction. And nearly no residues are left, the cleaning work
will be easy.
4. Automatic and manual starting modes, better system compatibility
5. Fire extinguishing agent is innocuous, harmless, scientific and
environmental. No any polluted gas and substances generated.
6. Widely application use of condensed aerosol generators
FireLess 100 Condensed Aerosol Generators Information
Product name | FireLess 100 Condensed Aerosol Generators For Fire Extinguishing For Class ABCE Fires |
Protected volume | 100m3 |
Fire extinguishing agent quantity | 2.8kg |
Dimension | 240mm(diameter)x110 |
Electric activator | 1 piece |
Extinguishing fire class | A,B,C,E |
Discharge time | ≤15s |
Main components | Mounting brackets, tank of fire extinguishing device, electric starter |
Working temperature | -50℃~+95℃ |
Start current | ≥700mA, DC |
Safe current | ≥150mA, DC |
Starting device | Passive /Active |
Design style | Compact and modular |
Effective time | 10 years |
Typical application use | Big document rooms, warehouses, underground cable well, equipment rooms |
certificate | Type testing certification |
Product inspection
1. Please inspect the product after opening the box of FireLess 100 Aerosol Automatic Fire
2. Extinguishing Device which includes fire extinguishing device tank,bracket and electric trigger.
3. Device parts should be firmly connected. No loosening should occur.
4. The tank of fire extinguisher should be covered with red insulation coating.If the insulation coating is off, please contact it in time.
Attention
1. The device should be installed evenly in the protective space, and the distance between them should be not less than 2 meters. When the height of protective space is greater than 5 meters, it can be installed in layers, and the distance between layers should not be greater than 5 meters.
2. When in installation, the device must be considered to avoid high temperature area with temperature above 95°C. There should be no obstacles or flammable and explosive substances that affect the free spray of aerosol within 1 meters around the shell.
3. After the device has completed spray and release, its shell is at high temperature and should not be touched. Disposal of the device should be implemented after cooling through nature or other methods.