Europe Standard Dn1200 Electromagnetic Flow Sensor Flowmeter Converter

Brand Name:VACORDA
Certification:CE/TUV/ISO9001/SGS
Model Number:HKLD
Minimum Order Quantity:1 Piece/Pieces
Place of Origin:Sichuan, China (Mainland)
Price:$150.00 - $350.00 / Pieces
Contact Now

Add to Cart

Active Member
Location: Zigong Sichuan China
Address: No. 41, Chengxi Rd, Yantan industrial zone, Yantan dist., Zigong city, Sichuan province, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Europe Standard Dn1200 Electromagnetic Flow Sensor Flowmeter Converter


HKLD intelligent electromagnetic flowmeter is a kind of fully intelligent electromagnetic flowmeter developed by our company with advanced technology at home and abroad. Its Chinese electromagnetic converter core uses high-speed central processing unit. The calculation speed is very fast, the accuracy is high, and the measurement performance is reliable.


Electromagnetic Flow Meters are based on FARADAY'S LAW INDUCTION. These meters are also called as Magflow or Electromagnetic Flow Meters. A magnetic field is applied to the metering tube, which results in a potential difference proportional to the flow velocity perpendicular to the flux lines. The physical principle at work is electromagnetic induction and mathematically defined as E=k*B*D*V.


Features

(1) The obstruction to the flow is almost nil and therefore this type of meters can be used for measuring heavy suspensions, including mud, sewage and wood pulp.

(2) There is no pressure head loss in this type of flow meter other than that of the length of straight pipe which the meter occupies.

(3) They are not very much affected by upstream flow disturbances.

(4) They are practically unaffected by variation in density, viscosity, pressure and temperature.

(5) Electric power requirements can be low (15 or 20 W), particularly with pulsed DC types.

(6) These meters can be used as bidirectional meters.


Product Parameters

Product Name

Electromagnetic Flowmeter

Repeatability error

+/-0.1%

Accuracy class

0.5 class, 1.0 class

Measured medium temperature

Common rubber lining: -20~+60 ° c

High temperature rubber lining: -20~+90 ° c

PTFE lining: -30~+100 ° c

High temperature vinyl lining: -30~+180 ° c

Rated working pressure

pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

DN200~DN1200: ≤ 1.0MPa

Flow rate range

0.3~15m/s

Measured fluid conductivity

≥5μs/cm liquid

Output

4~20mA / 4~20mA + Hart

Electrode material

316L, titanium (Ti), tantalum (Ta), Hastelloy (H),

Platinum (Pt) or other special electrode materials

Working power supply

85~265VAC / 24VDC / Battery

Straight pipe length

pipe: ≥ 5DN in the upper reaches, downstream of

greater than or equal to 2DN


Protection grade

standard: IP65; IP68(optional)

Explosion-proof mark

mdllBT4


Deatail Images


China Europe Standard Dn1200 Electromagnetic Flow Sensor Flowmeter Converter supplier

Europe Standard Dn1200 Electromagnetic Flow Sensor Flowmeter Converter