Add to Cart
160ah lifepo4 cell LFP Lithium Li Ion 3.2V 160Ah LiFePO4 Battery Cell for EV
Advantages of LFP
These battery cells are suitable for all traction applications
including electric vehicles. Fully complies also for stationary
applications - such as energy storage.
There is no Selfdischarging effect.
Can be recharged at any state of discharge - no memory effect
LiFePO4 is a very safe technology, not spontaneous combustion, does
not react with moisture or with oxygen.
High power lithium cell, original Winston Battery product with LiFePO4 (LiFeYPO4) technology. Capacity: 160Ah, size: 278x182x71 mm, weight: 5.8 kg. Model: 160AHA(A)
Specifications | ||
Model name | 160ah lifepo4 cell | |
Nominal voltage | 3.2V | operating voltage under load is 3.0V |
Nominal capacity | 160Ah | +/-5% |
Operating voltage | max 4.0v-min 2.8v | At 80% DOD |
Deep discharge voltage | 2.5V | The cells is damaged if voltage drops bellow this level |
Max charge | 4V | The cells is damaged if voltage drops bellow this level |
Weight(kg) | 5.8kg | (+/-150g) |
Height (mm) | 278mm | (+/-2mm) |
Width (mm) | 182mm | (+/-2mm_ |
Depth (mm) | 71mm | (+/-2mm) |
Peak discharge current (A) | 1600A | 10C |
Max continuous discharge current | 480A | 3C |
Optimal discharge current (A) | 80A | 0.5C |
Max charging current (A) | 480A | 3C with battery temperature monitoring |
Optimal charging current (A) | 80A | 0.5C |
Pictures
Size of packs using 160Ah cells
1 cell: Capacity 480 Wh / Depth 71 mm / Weight 5.8 kg | 8 cells, 24V Total capacity 3840 Wh / Depth 568 mm / Weight 46.4 kg |
4 cells, 12V Total capacity 1920 Wh / Depth 284 mm / Weight 23.2 kg | 16 cells, 48V Total capacity 7680 Wh / Depth 1136 mm / Weight 92.8 kg |
User manual
Lithium cells and batteries LiFePO4 (LFP) – LiFeYPO4 (LFYP)
WARNING: Always check the technical specification of the cells and other products BEFORE the installation. Check the voltage, polarity, dimensions, mechanical shape, the proper design of the terminals, etc. Be sure to report any strange conditions to us BEFORE the operation and installation of the cell or other product. We will be happy to provide support for any irregular situation.
Initial charging
New batteries LFP/LFYP are partly charged from factory. However,
before first use it is absolutely necessary to charge the battery
to full capacity. This initial charging should be done at maximum
current of 1C and the voltage level according to the specification
of the cell or battery. Please see specifications of the cell about
value of initial charging. Battery capacity in the first cycle
gradually grows. In the first few cycles is recommended to avoid
rapid discharge to the minimum capacity and we do not recommend
quick charging. After about the fifth, sixth cycle, is nothing to
prevent the batteries used in full operating cycle according to the
manufacturer's specifications for the type of battery.
Standard charging
Because LiFePO4 batteries has no memory effect, charging can be
done at any time. Repeated short charge cycles the battery life not
significantly changed (within + / - 5%).
Discharging
WARNING: Carefully check the minimum voltage as specified cells or
batteries. Discharging below this voltage will damage the battery
and void the warranty.
Maximum discharging currents for single cells or batteries are
listed in the manufacturer's specifications for the type of cell.
Battery and cell checking
Battery check and match any individual cell or battery is done by
charging the cells in series, connecting the charger to each
individual battery. Checking the battery status and any match is
recommended to perform these intervals (ie, discharge / charge
cycle):
first charge
after the first cycle
after the 5 cycles
after the 20 cycles
after the 50 cycles
possibly followed by further the anomalies detected about once
every 50 to 200 cycles
The rules for use and storage of batteries
Protect from improper handling.
Do not insert with opposite polarity, follow the signs. If the
batteries are inserted in reverse, can cause a short-circuit or
charging.
Prevent short-circuiting. If possitive (+) and negative (-) battery
terminals are connected, short-circuiting happens.
Before installing, clean the terminals of battery and the terminals
facilities.
The LiFePO4 should be always mounted with the terminals facing
upwards.
Do not heat excessively. – batteries operate at temperatures
according to the specifications.
Do not weld the cells.
Do not disassemble. When open may be contact with different parts
of the battery harmful.
Do not distort. Batteries should not be compressed, punctured or
damaged in any way.
Do not dispose of in fire.
Do not expose to water or excessive humidity.
Keep away from children. Beyond their reach, it is necessary first
of all to keep away batteries which can be swallowed. In addition,
children should not be allowed replacement of batteries without
adult supervision.
Do not incase or modify. Any modifying of the battery may cause
block safety ventilation mechanism. Any adjustments should consult
the dealer.
Unused batteries should be stored charged and keep them away from
metal subjects, which can make short-circuiting the battery.
Alreary unpackage units should not be mixed and stored with unused
batteries.
Avoid extreme humidity (over 95%) High temperature or humidity may
worsening of battery characteristics and / or corrosion of the
surface.
Do not storage / expose the battery to direct sunlight, in places
where they may be exposed to rain, excessive heat such as radiators
or heaters.
Batteries stored in well-ventilated and dry environment, ideally
enclosed in a protective case.
During storage, keep the temperature within the range according to
the specifications of a particular article.
Do not mix with other materials.
Do not stack cardboard box with batteries. When stacking may cause
deformation of the battery in the lower layers and the subsequent
flow of electrolyte.
For additional transportation / handling and packing materials,
choose the method of packaging to prevent unintentional electrical
contact and corrosion terminals, providing protection against
environmental influences and mechanical damage.
Considerate handling of the boxes. Rough handling can cause a short
circuit or damage.
Ensure proper circulation of stocks, follow FIFO system (First In,
First Out).
Check the voltage of the cell every 2 month. Charge the cell if the
voltage dropped to a minimum value of voltage