Energy Saving CNG compressor for compressed natural gas
Application:
The CNG compressor is used for CNG mother station and low pressure
daughter station.
Features:
The CNG compressor unit is skidded as a whole, and the motor drives
the compressor directly through the coupling. It is convenient to
transport and easy to install.
Compressor can be equipped with sound insulation cover to meet
all-weather outdoor operation. The cover is equipped with space
heater, flammable gas alarm system, maintenance suspension beam,
explosion-proof lighting, safety door, adjustable shutter and
special silencing channel. It is safe, environmental friendly and
convenient to maintain.
The lubrication system is equipped with advanced lubricant heating
system and pre-lubrication system, which can automatically control
the temperature of lubricating oil and ensure the lubrication of
key parts such as crosshead slideway.
The service life of vulnerable parts (air valve, packing seal,
piston ring and supporting ring) reaches 6000-8000 H.
Technical parameters:
S/N | Model | Inlet pressure (Mpa) | Power (KW) | Capacity(Nm3/h) | Cooling style |
1 | M-9/0.5-250A-JX | 0.5 | 185 | 755 | water cooling |
2 | M-10.5/0.5-250-JX | 0.5 | 220 | 900 | water cooling |
3 | M-7.3/0.6-250A-JX | 0.6 | 160 | 660 | Mixed cooling |
4 | M-8.0/0.7-250-JX | 0.7 | 185 | 775 | Mixed cooling |
5 | M-6.3/1-250-JX | 1 | 160 | 690 | water cooling |
6 | M-8.45/1-250-JX | 1 | 220 | 950 | air cooling |
7 | M-7.3/1.4-250-JX | 1.4 | 220 | 990 | water cooling |
8 | M-3.8/2-250B-JX | 2 | 132 | 620 | Mixed cooling |
9 | M-4.5/2-250A-JX | 2 | 160 | 750 | water cooling |
10 | M-5/2-250B-JX | 2 | 185 | 870 | Mixed cooling |
11 | M-5.5/2-250-JX | 2 | 200 | 940 | water cooling |
12 | M-6.1/2-250-JX | 2 | 220 | 1035 | water cooling |
13 | M-4.5/2.5-250-JX | 2.5 | 185 | 900 | water cooling |
14 | M-5.36/2.5-250-JX | 2.5 | 220 | 1070 | water cooling |
15 | M-6.1/2.5-250-JX | 2.5 | 250 | 1220 | water cooling |
16 | M-3/3-250-JX | 3 | 132 | 660 | Mixed cooling |
17 | M-3.65/3-250A-JX | 3 | 160 | 805 | Mixed cooling |
18 | M-4.1/3-250A-JX | 3 | 185 | 930 | water cooling |
19 | M-4.9/3-250-JX | 3 | 220 | 1110 | water cooling |
20 | M-5.45/3-250B-JX | 3 | 250 | 1250 | water cooling |
21 | M-6.35/3-250-JX | 3 | 280 | 1420 | Mixed cooling |
22 | M7.1/3-250B-JX | 3 | 315 | 1595 | water cooling |
23 | M-3.65/3.5-250-JX | 3.5 | 185 | 960 | water cooling |
24 | M4.05/3-250-JX | 3.5 | 200 | 1040 | Mixed cooling |
25 | M-5.6/3.5-250-JX | 3.5 | 280 | 1450 | water cooling |
26 | M-3.4/4-250-JX | 4 | 185 | 980 | water cooling |
27 | M4.1/4-250-JX | 4 | 220 | 1170 | Mixed cooling |
28 | M-4.75/4-250-JX | 4 | 250 | 1330 | Mixed cooling |
29 | M-5.2/4-250-JX | 4 | 280 | 1490 | water cooling |
30 | M-2/6-250-JX | 6 | 132 | 760 | water cooling |
31 | M3.8/6-250-JX | 6 | 250 | 1470 | water cooling |
32 | M4.05/6-250-JX | 6 | 280 | 1630 | water cooling |
33 | M-5.4/6-250-JX | 6 | 355 | 2100 | water cooling |
34 | M-3.3/7-250-JX | 7 | 250 | 1520 | Mixed cooling |
35 | M-2.3/8-250-JX | 8 | 185 | 1170 | Mixed cooling |
36 | M3.6/8-250-JX | 8 | 280 | 1770 | water cooling |
37 | M-2.15/10/250-JX | 10 | 200 | 1345 | water cooling |
38 | M-2.36/10-250B-JX | 10 | 220 | 1480 | water cooling |
39 | M-2.75/10-250-JX | 10 | 250 | 1690 | water cooling |
40 | M-3.2/10-250-JX | 10 | 280 | 1890 | water cooling |
41 | M-3.45/10-250-JX | 10 | 315 | 2130 | water cooling |
42 | M-2.4/12-250-JX | 12 | 250 | 1780 | water cooling |
43 | M-3/12-250-JX | 12 | 315 | 2240 | water cooling |
44 | M-3.35/12-250A-JX | 12 | 355 | 2530 | water cooling |
45 | M-2.3/13-250-JX | 13 | 250 | 1830 | air cooling |
46 | M2.75/13-250-JX | 13 | 315 | 2310 | water cooling |
47 | M-2.27/14-250-JX | 14 | 250 | 1875 | Mixed cooling |
48 | M2.68/14-250-JX | 14 | 280 | 2080 | air cooling |
49 | M-1.86/15-250-JX | 15 | 220 | 1680 | Mixed cooling |
50 | M-2.7/15-250C-JX | 15 | 280 | 2150 | Mixed cooling |
51 | M-1.32/16-250-JX | 16 | 160 | 1250 | water cooling |
52 | M2.05/16-250-JX | 16 | 250 | 1965 | water cooling |
53 | M-2.6/16-250D-JX | 16 | 315 | 2470 | Mixed cooling |
54 | M-2.75/17-250-JX | 17 | 315 | 2520 | water cooling |
55 | M-2.48/18-250D-JX | 18 | 315 | 2580 | Mixed cooling |
56 | M-1.75/20-250-JX | 20 | 250 | 2110 | water cooling |
57 | M-2.1/20-250-JX | 20 | 280 | 2375 | water cooling |
58 | M-2.21/22-250-JX | 22 | 315 | 2880 | water cooling |
59 | M-2/28-250-JX | 28 | 315 | 3210 | water cooling |
60 | M-1.15/30-250-JX | 30 | 220 | 2215 | water cooling |
61 | M-1.58/30-250-JX | 30 | 280 | 2815 | water cooling |
62 | M-1.75/30-250A-JX | 30 | 315 | 3160 | Mixed cooling |
63 | M-1.5/35-250-JX | 35 | 280 | 3040 | Mixed cooling |
64 | M-1.4/40-250-JX | 40 | 280 | 3200 | Mixed cooling |
65 | M-1.5/40-250-JX | 40 | 315 | 3580 | water cooling |
66 | M-1.12/45-250-JX | 45 | 250 | 3060 | water cooling |
67 | M-1.65/45-250-JX | 45 | 355 | 4340 | water cooling |