Hazardous area surge protection device for 4-20mA measuring control & bus system


Installed at LPZ OB-2 or higher inside the control equipment, the built-in cable connected with the control equipment’s wiring terminal. TS-24 hazardous area surge protection device is available to apply in intrinsically safe circuit in hazardous areas and 4-20mA measuring control system and bus system.


  • Technical Data of TS-EX24 Hazardous area surge protection equipment
Model NumberTS-EX24
Normal VoltageUn24V-
Rated voltage (max. continuous voltage)Uc

32V-

22.6V ~

Lightning impulse current (10/350)Iimp1.5kA
Normal currentIL0.55A
Nominal discharge current (8/20)In10kA (per line); 10kA(total)
Voltage protection level at InUp≤ 58V (line/line); ≤ 1700V (line/PG)
Voltage protection level at 1kV/μsUp≤ 50V (line/line); ≤ 1200V (line/PG)
BandwidthfG67MHz
CapacitanceC≤ 25pF (line/line); ≤ 15pF (line/PG)
Operating temperature range-40 0C ~ +80 0C
Mounting inM20 x 1.5 screws
Connection (input / output)1.3 mm x 250mm length of the connecting lead
Earthing viaConnecting lead
Enclosure materialStainless steel case
ComplianceIEC-61643-21, GB18802.21, YD/T 1542

  • MAIN CHARACTER
  1. Small & easy replacement.
  2. Easy to install inside the control equipment.
  3. Stainless steel housing, fireproof & explosion-proof outdoor use.

Installation Instruction

  • Screwing into the wiring port of the control equipment directly
  • Blue wire connecteed with signal port “+”, Black Wire connected with signal port “-”
  • Yellow / Green wire connect with grounding port “GN” of grounding system.
  • After installation, check if commuication is be operating normally.

Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD.


INSTALLATION DIAGRAM


WARNING:

  • The hazardous area surge protection device must be installed by electrically skilled person, conforming to national standards and safety regulations.
  • It is recommended that installation should be done under power off condition.