TSTLP Industrial bus control / RS422 / RS485 surge protection devices



TSTLP TS-RS485/5 RS485 surge protection devices comply with IEC 61643-21 for installation at LPZ 0B -2 or higher.Provide RS422 / RS485 surge protection for Industrial bus control,other field bus and temperature measurement.


  • Technical Specification Part 1
ModelTS-RS485/5
Nominal voltageUn5V-
Rated voltage (max. continuous voltage)Uc6V- / 4.2V~
Nominal currentIL0.5A
Nominal discharge current (8/20)In10kA
Voltage protection level at InUp≤ 20V (line-line)
≤ 700V (line-PG)
Voltage protection level at 1KV/µsUp≤ 8.5V (line-line)
≤ 600V (line-PG)
Response timetA≤ 1ns (line-line)
≤ 100ns (line-PG)
BandwidthfG1.7MHz
Series impedance per lineR1.8Ω
CapacitanceC≤ 5nF

Technical Specification Part 2


  • Features
  1. RS422 / RS485 Industrial Voltage Surge Protector Yellow
  2. Quick response,Low voltage protection level
  3. Direct or indirect shield earthing
  • Installation Instruction
  1. The RS485 surge protection devices are connected in series to the protected device.
  2. The out terminal should be connected to the protected devices.
  3. There is a earthing terminal at input side,earth lead must be connected to the lightning earthing system,ideally using 2.5mm² cable. The cable should be as short as possible.
  4. Shields on the TS-RS485/5 can be grounded directly or indirectly. If grounded directly,the shield of the incoming cable is connected to terminal 8(IN) and the outgoing cable is connected to terminal 8´(OUT).

If grounded directly,the shield of the incoming cable is connected to terminal 7(IN) and the outgoing cable is connected to terminal 7´(OUT).

Regularly inspect the operating status, especially after lightning/surge. Once the communication is off, electrician should check/replace the RS485 surge protection devices.


  • Installation Diagram


PDF Catalog Download - TS-RS485-5 SPD.pdf


PDF Catalog Download - TS-ITS-ME SERIES SPD.pdf


Tag: rs485 surge protection, rs485 surge protection devices

China Industrial Bus Control Industrial Surge Protector , RS422 / RS485 Voltage Surge Protector supplier

Industrial Bus Control Industrial Surge Protector , RS422 / RS485 Voltage Surge Protector

Inquiry Cart 0