The multifunctional curing oven using industrial control chip, PID algorithm control temperature,can set temperature and time , the digital display temperature, a buzzer to alert. Provide good human-machine interface, effectively improve the curing speed.

Parameter

  • Voltage:AC220V/50Hz
  • Power:1000W
  • Control range:0~200℃
  • Control percise:±1℃
  • Timer range:1~99min 99seconds
  • Machine Dimension:405×320×135mm
  • Net weight:6.5KG
  • Package dimension:400×490×180mm

Setting temperature


Press and hold the “SET” key for 5 seconds, can enter the temperature setting pattern, the number will be shine, Press the “<” key to set up temperature of number. Press the “︽” key to increase the temperature in operation, press “︾” key to reduce temperature in operation. And press the”SET” key to exit temperature setting. When the set time,If don’t press any key within 10 seconds.

It will automatic exit temperature setting.


Setting time


Press and hold the”>” key for 10 seconds to enter setting time mode,Display will be(03-2). It will be automatic stop after 5 seconds. At this time,press this button again then the number will be shine on the left. Press the “>” key to confirm the ones,tens hundreds and thousands. Press the”︽” key to adjustment the times. It will be automatic stop after 5 seconds. When the set time,If don’t press any key within 10 seconds,It will automatic exit time setting.


Time activation


Press the”RST” key, the timer start to count down,Display automatically switches to the countdown time. When the timer time display is same with the set time display. The buzzer will alert. When press the key of “RST” again will be stop timing alert. And then to work next time must press the key of “RST” to start for timer.