High Performance Transit Time Ultrasonic Flow Meter With 16GB Data Logger

Brand Name:Lanry
Certification:CE
Model Number:TF1100-EI
Minimum Order Quantity:1 Unit
Place of Origin:Shanghai, China (Mainland)
Price:Negotiable
Contact Now

Add to Cart

Site Member
Location: Shanghai Shanghai China
Address: 8 Floor, Block C, Bldg 5, No.2800 Jiuxin Rd., Songjiang District, Shanghai,201612, China
Supplier`s last login times: within 24 hours
Product Details Company Profile
Product Details
Insertion flow meter of Transit time principle TF1100-EI with insertion flow sensor
The Ultrasonic flow calculator can display the velocity, level, flow rate and flow totalizer. The insertion flow meter of Transit time also can be available with 4-20mA, RS232, RS485 (Modbus) /GPRS and SD card logger outputs. Insertion flow meter of Transit time provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion type has the advantage of long-term stability and better accuracy.
Insertion flow meter of Transit time principle TF1100-EI with insertion flow sensor Features:
1. Hot-tapped installation, no pipe line flow interrupted
2. Wide liquid temperature range: -35℃~200℃.
3. Wide bi-directional flow range of 0.01 m/s to 12 m/s..
4. Thermal energy measurement capability can be optional.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Data logger function for insertion ultrasonic flow meter


Application

General
● Service and maintenance

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

Specifications:Transmitter


Measurement principleUltrasonic transit-time difference correlation principle
Flow velocity range0.01 to 12 m/s, bi-directional
Resolution0.25mm/s
Repeatability0.2% of reading
Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time0.5s
Sensitivity0.003m/s
Damping of displayed value0-99s(selectable by user)
Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
Power SupplyAC: 85-265V DC: 24V/500mA
Enclosure typeWall-mounted
Degree of protectionIP66 according to EN60529
Operating temperature-20℃ to +60℃
RateRate and Velocity Display
Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
Thermal energyunit GJ,KWh can be optional
Communication4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
SecurityKeypad lockout, system lockout
Size244*196*144mm
Weight2.4kg

Specifications:Transducer


Degree of protectionIP67 or IP68 according to EN60529
Suited Liquid TemperatureStd. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter rangeDN65-6000
Transducer SizeType S Φ58*199mm
Material of transducerStainless Steel
Cable LengthStd: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%



Packing & Delivery


Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application


With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

China High Performance Transit Time Ultrasonic Flow Meter With 16GB Data Logger supplier

High Performance Transit Time Ultrasonic Flow Meter With 16GB Data Logger

Inquiry Cart 0