PCB Mount Hall Effect Current Transformer Ac Current Transducer TBC-C104/204

Brand Name:TOKEN
Certification:CE;ROHS
Model Number:TBC-C204
Minimum Order Quantity:10pcs
Place of Origin:CHINA
Price:Price Reconsideration
Contact Now

Add to Cart

Active Member
Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

PCB Mount Hall Effect Current Transformer Ac Current Transducer


TBC-C104/204 multi-range current sensor is a close loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit .It provides accurate electronic measurement of DC,AC or pulsed currents.

Electrical data(Ta=25℃±5℃)

Type
Parameter
TBC25C104TBC50C204


Uuit


Rated input (Ipn)
2550A

Measure range(Ip)
0~±600~±120A

Measure resister range
200~730(±15V)54~250(±15V)Ω
Turns ratio(Np/Ns)1-2-3:20001-2-3-4:2000

Rated output (Isn)
±12.5±0.5%(Ip=±Ipn)±25±0.5%(Ip=±Ipn)mA
Supply voltage±15±5%V
Power consumption20+IpX(Np/Ns)mA

Zero offset current
@Ip=0 ≤±0.2mA

Offset current drift
@ -40℃~+85℃ ≤0.5mA

Response time
@50A/μS,10%-90% <1µs


Linearity

@Ip=0-±Ipn ≤0.1%FS

Galvanic isolation
@ 50HZ/60HZ,AC,1min 5KV
di/dt accurately followed>50A/μs

Bandwidth(-3dB)
DC…100KHz

Secondary coil resister
200180Ω
Applications

Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical

Mechanical dimension(for reference only)


Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.

Pin connections

Primary
turns


Rated
current
IPN(A)

Rated
output
IS(mA)

Primary
resister
[mΩ]

Pins connections
TBC25C104TBC50C204


1


25, 50


12.5,25


0.05


2


12, 24


12, 24


0.20


3


8, 16


12, 24


0.48


4


12


24


1.00

Directions for use

When the current will be measured goes through a sensor ,the current will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
Custom design in the different rated input current and the output current available.

Standards

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000
General date
ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)15gM

Characteristics chart

Pulse current signal response characteristic Effects of impulse noise