Split Core Current Transformer Hall Effect Based Current Sensor PCB Mounting

Brand Name:TOKEN
Certification:CE;ROHS
Model Number:TBC- E
Minimum Order Quantity:10pcs
Place of Origin:CHINA
Price:Price Reconsideration
Contact Now

Add to Cart

Active Member
Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Split Core Current Transformer Hall Effect Based Current Sensor PCB Mounting


The TBC- Eseries current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.


Electrical data(Ta=25℃±5℃)

Type

Parameter
TBC50ETBC75ETBC100ETBC200ETBC300E

Unit


Rated input (Ipn)
5075100200300A

Measure range(Ip)
120200250450500A

Turns ratio(Np/Ns)
1:10001:15001:10001:20001:3000T

Internal measuring resister
80±0.1%80±0.1%40±0.1%40±0.1%40±0.1%Ω

Rated output
@Ip=±Ipn ±4±0.5%V

Supply voltage
±15 ±5%V
Power consumption≤20+IpX(Np/Ns)mA

Zero offset voltage
@Ip=0 ≤±10mV

Offset drift
@ -40~+85℃ ≤±0.5mV/℃

output drift
@ -40~+85℃ ≤±0.5mV/℃

Linearity
@Ip=0-±Ipn ≤0.1%FS

Response time
@100A/μS,10%-90% ≤1μS

Bandwidth
@ -3db DC~100KHZ

Galvanic isolation
@ 50HZ,AC,1min 3KV

Applications

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical


Mechanical dimension(for reference only)

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.


Directions for use

Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.

The primary conductor should be≤120℃.

The dynamic performance (di/dt and the response time)is the best when the primary hole is fully filled with

the bus bar.

The primary turns should be at the top of the sensor for the best magnetic coupling.

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor).

Custom design in the different rated input current and the output voltage are available.


Standards


  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date

ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)44gM

Characteristics chart

Pulse current signal response characteristic Effects of impulse noise

China Split Core Current Transformer Hall Effect Based Current Sensor PCB Mounting supplier

Split Core Current Transformer Hall Effect Based Current Sensor PCB Mounting