Add to Cart
Null Balance Closed Loop Hall Effect Current Sensor High Precision TBC1000LF
TBC1000LF high precision Closed Loop Hall Effect Current Sensor
The TBC1000LF current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current sensor, It can really measure resolution 1000:1 and it uses for precision measurement of DC, AC and pulse current.
TBC1000LF high precision Closed Loop Hall Effect Current Sensor Electrical data(Ta=25℃±5℃)
model Parameter | TBC1000LFA | Unit |
Rated input Ipn) | 10-1000 | A |
Measure range(Ip) | 2000 | A |
coil resister | @ 85℃ 48 | Ω |
Measure resister | with±15V @±1000Amax 0(min) 20(max) | Ω |
with±15V @±1200Amax 0(min) 7.5(max) | Ω | |
with±24V @±1000Amax 0(min) 65(max) | Ω | |
with±24V @±2000Amax 0(min) 7.5(max) | Ω | |
Turns ratio(Np/Ns) | 1:5000 | |
Rated output (Isn) | 2±0.1%FS(10A), 200±0.1%FS(1000A) | mA |
Supply voltage | ±15~±24 | V |
Power consumption | ≤20+IpX(Np/Ns) | mA |
Zero offset | @Ip=0 ≤±0.2 | mA |
Offset drift | @ -40℃~85℃ ≤±0.5 | mA |
Response time | @100A/μS,10%-90% <1 | µs |
Linearity | @Ip=0-±Ipn ≤0.05 | %FS |
Galvanic isolation | @ 50HZ, AC, 1min 6 | KV |
di/dt accurately followed | >100 | A/µs |
Bandwidth | @ -3dB DC…150 | KHz |
TBC1000LF high precision Closed Loop Hall Effect Current Sensor Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
TBC1000LF high precision Closed Loop Hall Effect Current Sensor Mechanical dimension(for reference only)
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
TBC1000LF high precision Closed Loop Hall Effect Current Sensor
Directions
Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
The primary conductor should be≤120℃.
The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.
TBC1000LF high precision Closed Loop Hall Effect Current Sensor Standards
TBC1000LF high precision Closed Loop Hall Effect Current Sensor General date
Value | Unit | Symbol | |
Operating temperature | -40~+85 | ºC | TA |
Storage temperature | -40~+125 | ºC | TS |
Mass(approx) | 570 | g | M |
TBC1000LF high precision Closed Loop Hall Effect Current Sensor
Characteristics chart
Pulse current signal response characteristic Effects of impulse noise
Input signal/Output signal Output voltage