Multi Range Closed Loop Hall Effect Current Sensor Hall Effect High Current Sensor


TBC-A05 multi-range current sensor is a close loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit .It provides accurate electronic measurement of DC,AC or pulsed currents.


Electrical data(Ta=25℃±5℃)


Type

Parameter

TBC25A05TBC35A05

Unit


Rated input (Ipn)
2535A

Measure range(Ip)
5070A

Rated output (Isn)
±25±0.5%(@Ip=±Ipn)±35±0.5%(@Ip=±Ipn)mA

Secondary coil resister
4535Ω

Turns ratio(Np/Ns)

1-2-3-4-5:1000T

Supply voltage

±12~±18V

Consumption current
20+IpX(Np/Ns)mA

Zero offset current
@Ip=0 ≤±0.2mA

Offset current drift
@ -40℃~+85℃ ≤±0.5mA

Response time
@50A/μS,10%-90% <1µs

Linearity

@Ip=0-±Ipn ≤0.1%FS

Galvanic isolation
@ 50HZ,AC,1min 2.5KV

di/dt accurately followed

>50A/μs

Bandwidth
@ -3dB DC…150KHz

Applications


AC variable speed drives and servo motor drives

Static converters for DC motor drives

Variable speed drives

Power supplies for welding applications

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Switched Mode Power Supplies(SMPS)


Mechanical dimension(for reference only)



Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.


Pin connections



Turns

Rated current

IPN(A)


Measure range Ip(A)

Rated output Isn( mA)

Turns ratio


Primary resister
(mΩ)

Primary inductance (uH)

Pins connections
125(35)50(70)25(35)1/10000.30.023
212(17.5)24(35)24(35)2/10001.10.09
38(12)16(24)24(36)3/10002.50.21
46(9)12(18)24(36)4/10004.40.37
55(7)10(14)25(35)5/10006.30.58

Directions for use


When the current will be measured goes through a sensor ,the current will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)


Custom design in the different rated input current and the output voltage available.


Standards


  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date


ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)20gM

Characteristics chart