TBV-LV Hall Effect Voltage Sensor Dc Voltage Transducer Blue And Black

Brand Name:TOKEN
Certification:CE;ROHS
Model Number:TBV-LV
Minimum Order Quantity:10pcs
Place of Origin:CHINA
Price:Price Reconsideration
Contact Now

Add to Cart

Active Member
Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

TBV-LV Hall Effect Voltage Sensor Dc Voltage Transducer Blue And Black


TBV-LV series current mode voltage sensor is a device based on the principle of the hall effect, with a galvanic isolation between primary and secondary circuit, It provides accurate electronic measurement of DC,AC or pulsed voltage.


Electrical data(Ta=25℃±5℃)


Type

Parameter

TBV

100LV

TBV

200LV

TBV

300LV

TBV

500LV

TBV

1000LV

TBV

2000LV

TBV

3000LV

TBV

4000LV


Unit


Rated input (Vpn)
1002003005001000200030004000V

Measure range(Vp)
20040060010002000400060006000V

Total input consumption

0.250.500.751.252.55.07.510W

Rated input (Ip)

2.5mA

Turns ratio(Np/Ns)

20000:1000T

Secondary coil resister

@ +85℃ 55Ω

Rated output (Isn)
@Vp=±Vpn ±50±0.5%mA

Resister measured

@ ±15V VPN 50(min), 200(max)Ω
@ ±15V 2XVPN 0(min), 100(max)Ω
@ ±24V VPN 100(min), 330(max)Ω
@ ±24V 2XVPN 100(min), 200(max)Ω

Supply voltage
±15 - ±24V

Consumption current
20+IpX(Np/Ns)mA

Offset current
@ Vp=0 ≤±0.2mA

Offset drift
@ -40~+85℃ ≤±0.6mA

Linearity
@ Vp =0-±Vpn ≤0.1%FS

Response time
≤200uS

Galvanic isolation
@ 50HZ,AC,1min Between primary and secondary + shield 12.0KV
@ 50HZ,AC,1min Between secondary and shield 2.0KV

Applications


Variable speed drives

Power supplies for welding applications

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Switched Mode Power Supplies(SMPS)


Mechanical dimension(for reference only)

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm


Directions for use

Is is positive when the Ip is applied to the terminal +HT. Temperature of the primary conductor should not exceed 100℃.

When the voltage will be measured goes through a sensor, the current will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

Custom design in the different rated input voltage and the output current available.


Standards


  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date


ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)43gM

Effects of impulse noise