2000A High Accuracy Hall Effect Current Sensor For DC AC Or Pulsed Currents Measurement

Brand Name:TOKEN
Certification:CE;ROHS
Model Number:TKC-HAT series
Minimum Order Quantity:10pcs
Delivery Time:7~10 working days
Payment Terms:L/C, T/T, D/P, Western Union
Contact Now

Add to Cart

Active Member
Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Open Loop Mode Dismountable Hall Effect Current Sensor For DC, AC Or Pulsed Currents Measurement


Deatails


The TKC-HAT series current sensor series is a open loop device based on the principle of the hall effect, with a galvanic isolation between primary and secondary circuit, It provides accurate electronic measurement of DC, AC or pulsed currents.


Regarding accuracy, currently available Hall effect sensors can achieve output error as low as 1%. A well-designed resistive current-sense circuit could surpass this, but 1% would generally be adequate in the high-current/high-voltage applications for which Hall effect devices are particularly suitable.


Applications


Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical


Electrical data (Ta=25℃±5℃,RL=2KΩ,CL=10000PF)

Type
Parameter

TKC

200HAT

TKC

400HAT

TKC

500HAT

TKC

600HAT

TKC

750HAT

TKC

800HAT

TKC

1000HAT

TKC

1200HAT

TKC

1500HAT


Unit

Rated input (Ipn)±200±400±500±600±750±800±1000±1200±1500A
Measure range(Ip)±600±1200±1500±1800±2250±2400±3000±3000±3000A
Rated output@ IP=±IPN ±4±1%V
Supply voltage±15 ±5%V

Consumption current

@ Is=0 +28,-15mA
Offset voltage≤±20mV
Magnetic offset@ IP=±IPN -0 ±15mV
Offset drift≤±1.0mV/℃
output drift≤±1.0mV/℃
Linearity@ IP=0-±IPN ≤1%FS
Response time@50A/μS, 10%-90% ≤5μS

Bandwidth

@ -3dB DC-25KHz
Galvanic isolation@ 50HZ/60HZ,AC,1min 3KV

Isolation resistance

@ DC 500V 1000

Mechanical dimension(for reference only)


Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.


Directions for use

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)


Customs can adjust Output amplitude of the sensor by needs.


Custom design in the different rated input current and the output voltage are available.


Standards


  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date

ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40to +125ºCTS
Mass(approx)290gM

Characteristics chart

Pulse current signal response characteristic Effects of impulse noise


China 2000A High Accuracy Hall Effect Current Sensor For DC AC Or Pulsed Currents Measurement supplier

2000A High Accuracy Hall Effect Current Sensor For DC AC Or Pulsed Currents Measurement