Add to Cart
GYTS multi core armoured fiber optic cable outdoor 12 core steel armored cable
1. Description
The fiber,125μm,are positioned in a loose tube made of a high
modulus plastic.
The tubes are filled with water-resistant filling compound.
A FRP, sometimes sheathed with polyethylene(PE) for cable with high
fiber count, locates in the centre of core as a
non-metallic/metallic strength member.
Tubes(and fillers) are stranded around the strength member into a
compact and circular cable core.
The PSP is longitudinally applied over the cable core, which is
filled with the filling compound to protect it from water
ingress.
The cable is completed with a PE sheath.
2.Specifications
2.1 General Specifications
Cable Type | GYTS |
Fiber Type | SM |
Application | Long-distance communication, LAN |
Recommended installation methods | Aerial |
Environment | Outdoor |
Temperature Range | -40℃ to 70℃ |
2.2 Structure and Technical Specifications
Fiber Count | Nominal Diameter (mm) | Nominal (kg/km) | Max Fiber Per Tube | Max No. of (Tubes+fillers) | Allowable Tensile Load (N) | Allowable Crush Resistance (N/100mm) | ||
Short Term | Long Term | Short Term | Long Term | |||||
12 | 9.7 | 96 | 6 | 5 | 1500 | 600 | 1800 | 800 |
Note : This datasheet can only be a reference, but not a supplement to the
contract. Please contact the sales for the details.
3. We produce and test the cable complying with the following
standard
Mechanical Performance | |
Max Tension Performance | IEC 60794–1-2-E |
Max. Operation Tension | IEC 60794–1-2-E1 |
Crush Test | IEC 6079 –1-2-E3 |
Impact Test | IEC 60794–1-2-E4 |
Repeated Bending | IEC 60794–1-2-E6 |
Torsion Test | IEC 60794–1-2-E7 |
Cable bend | IEC 60794–1-2-E11A |
Attenuation Coefficient | ITU-T G.652 |
Structural Test | IEC-60793-1-20 |
Environmental Performance | |
Temperature Cycling | IEC 60794–1-2-F1 |
Water Penetration | IEC 60794–1–2-F5B |
Filing Compound Flow | IEC 60794-1-E14 |
4. Packing and Shipping
Cable is supplied in lengths as specified in PI or as requirement.
Each length will be shipped on a separate non-returnable wooden
drum. The minimum barrel diameter of the drum will not be less than
30 times the cable diameter.
The cable on each reel will be completely covered with a thermal
wrap which is fastened to the cable by packaging straps. This wrap
is reusable and provides excellent thermal and UV protection.
The cable ends will be sealed with plastic protection caps to
prevent water penetration. The ends will be easily accessible for
testing. A final inspection test report with attenuation
performance data for each fiber is attached inside the drum.
4. Our business philosophy