Add to Cart
NACA.XXXQ-S6 / VA Current Transducers
Product description
NACA xxxq-s6 / VA Series triple current sensor is suitable for accurate isolation measurement of AC, DC and pulse current. The primary side and secondary side are completely insulated during measurement.
Product Info
performance requirement | ||||||
Parameter name | Symbol | Unit | Parameter name | condition | ||
minimum value | Typical value | Maximum | ||||
Electrical parameters | ||||||
Maximum range | IP | A | 800A~1200A | For more details, please contact CRRC | ||
Storage temperature | TS | ℃ | -40 | 125 | ||
supply voltage | UC | V | 4.75 | 5 | 5.25 | |
Output voltage (linear) | Vout | V | Vout=(Uc/5)·(V0+G·Ip) | @UC | ||
sensitivity | G | mV/A | 2000/Ip | @UC=5V | ||
Zero output | VO | V | 2.5 | @UC=5V | ||
Current consumption | IC | mA | 39 | 45 | @ UC=5V,No load on Vout | |
Load resistance | RL | KΩ | 4.7 | 10 | ||
Load capacitance | CL | nF | 4.7 | |||
Output internal resistance | ROUT | Ω | 10 | DC | ||
performance parameter | ||||||
Zero output error | X0 | % | -0.75 | 0.75 | @TA=25℃,@UC=5V | |
-1 | 1 | @-40℃<TA<125℃,@UC=5V | ||||
Sensitivity error | εG | % | ±1 | @TA=25℃,@UC=5V | ||
±2 | @-40℃<TA<125℃,@UC=5V | |||||
Electric zero shift | VOE | mV | ±4 | |||
Magnetic zero shift | VOM | mV | ±3 | |||
Proportional error | ɛR | % | 0.5 | |||
Linearity error | εL | % | -1 | 1 | of full range | |
response time | tr | μs | 7 | |||
bandwidth | BW | kHz | 30 | @-3dB | ||
phase difference | ∆φ | ° | -4 | @DC to 1kHz |
Dimensional drawing |
Series size |