Add to Cart
AGM Battery Charger with Charge Current 24VDC 10A/25A/40A for RV
Combined with up to date technology and our knowledge with
batteries,
Trident smart battery charger was especially designed for mobile
and
marine application, it was an ideal solution for your battery
charging on
board.
Batteries will be permanently damaged by either overcharged or
remaining undercharged for any period of time. TRIDENT smart
battery
charger will continuously deliver right charging at any
circumstance with
built in battery management features which will be helpful in
prolonging
your battery life expectancy.
Features :
Specs
Model | BS1210 | BS1225 | BS1240 | BS1225-3 | BS1240-3 |
Electrical | |||||
Output voltage (PS mode) (Vdc) | 12.8V±0.256Vdc | ||||
Max Output current (A) | 10 | 25 | 40 | 25 | 40 |
Nominal input voltage (Vac) | 85-265VAC,50/60Hz | 165-265VAC,50/60Hz | |||
Charge algorithms | 5 steps. soft start, bulk, absorption, float, recycle | ||||
Temperature compensation | Automatically | ||||
Absorption voltage(Vdc) | AGM:13.5V,GEL:13.5V,LFP:13.5V,WET:13.7V | ||||
Floating voltage (Vdc) | AGM:14.4V,GEL:14.1V,LFP:14.4V,WET:14.7V | ||||
Charging current (A) | 10 | 25 | 40 | 25 | 40 |
Min battery voltage (Vdc) | 1 | 2 | |||
Efficiency | 88% | ||||
Input connector | Cable of 1.5 meter with CEE 7/7 plug | IEC socket | |||
Output connector | Fixed cable,2.5mm², 1 meter | M4 Screw (16mm²) | |||
Output | 1 | 1+1 | |||
Ripple noise | ≤200mVp-p | ||||
Regulation Accuracy | ≤2% | ||||
Cooling | Self cooling | Fan cooling | |||
Working Temperature | -20℃ -- +60℃ | ||||
Protection | |||||
Short circuit | Shutdown output, automatically restart when short circuit is removed | ||||
Reverse polarity | No charging | ||||
Charger over temp | Shut down the charger | ||||
Battery over temp | Shut down the charger | ||||
Standards | |||||
LVD | EN60335-1,EN60335-2-29 | ||||
EMC | EN55014-1,EN55014-2,EN61000-3-2,EN61000-3-3 | ||||
Structure | |||||
Out case | Aluminum+plastic | ||||
Dimension | 175*114*53mm | 249*165*74mm | 249*165*74mm | ||
Weight | 1.0KG | 1.6KG | 1.6KG | ||
IP class | IP20 | IP23 | |||
Insulation Resistance | ≥50MΩ | ||||
Dielectric strength | I/P-O/P:3.0KV,I/P-PG:1.5KV,O/P-PG:0.5KV |
Installation
BS Charger can be installed on a horizontal surface or vertically on a wall. Please see following instruction;