Add to Cart
1.2~1.7m³/min Two Stage Screw Air Compressor Energy 11KW Air
Cooling
◆ Product Description
We are the leading organization actively occupied in providing an
extensive series of Tandem Two Stage Screw Air Compressor. This
product is presented in numerous of specifications.
As a benchmark of this industry, we are involved in offering a huge
range of Tandem Two Stage Screw Air Compressor. Under the strict
guidance of our technical experts, the offered compressors are
precisely manufactured with the aid of ultra-modern techniques by
utilizing the finest quality components. The volumetric efficiency
of two-stage is better than single-stage compression. In addition,
the Screw Compressors are available in vivid technical
specifications.
⊙ Type air compressor pause
Specifacation | Cooling Style | Air Capacity (m³/min) | Discharge Pressure (bar) | Motor Power (kw) | Speed (r/min) | Voltage(V) Frequency(Hz) | Cooling Air Capacity (m3/min) | Joint pipe Size (inch) | Total Weight (kg) | Dimension(L*W*H) (mm) |
SRC-7.5SA | Air cooling | 0.85 | 7 | 5.5 | 2980 | 380V50Hz | 80 | 1/2″ | 230 | 850*735*990 |
0.8 | 8 | |||||||||
0.6 | 10 | |||||||||
0.4 | 13 | |||||||||
SRC-10SA | Air cooling | 1.1 | 7 | 7.5 | 2980 | 380V50Hz | 80 | 1/2″ | 410 | 850*735*990 |
1 | 8 | |||||||||
0.8 | 10 | |||||||||
0.6 | 13 | |||||||||
SRC-15SA | Air cooling | 1.7 | 7 | 11 | 2980 | 380V50Hz | 80 | 1/2″ | 475 | 1100*750*1150 |
1.6 | 8 | |||||||||
1.4 | 10 | |||||||||
1.2 | 13 | |||||||||
SRC-20SA | Air cooling | 2.4 | 7 | 15 | 2980 | 380V50Hz | 100 | 1″ | 560 | 1350*850*1150 |
2.2 | 8 | |||||||||
2.1 | 10 | |||||||||
1.7 | 13 | |||||||||
SRC-25SA | Air cooling | 3.1 | 7 | 18.5 | 2980 | 380V50Hz | 145 | 1″ | 580 | 1350*850*1150 |
2.9 | 8 | |||||||||
2.7 | 10 | |||||||||
2.2 | 13 | |||||||||
SRC-30SA | Air cooling | 3.8 | 7 | 22 | 2980 | 380V50Hz | 145 | 1″ | 640 | 1350*850*1150 |
3.5 | 8 | |||||||||
3.2 | 10 | |||||||||
2.7 | 13 | |||||||||
SRC-40SA | Air cooling | 5.2 | 7 | 30 | 2980 | 380V50Hz | 255 | 1″ | 900 | 1350*850*1150 |
5 | 8 | |||||||||
4.3 | 10 | |||||||||
3.7 | 13 | |||||||||
SRC-50SA | Air cooling | 6.4 | 7 | 37 | 2980 | 380V50Hz | 255 | 1½″ | 980 | 1550*950*1450 |
5.9 | 8 | |||||||||
5.5 | 10 | |||||||||
4.8 | 13 | |||||||||
SRC-60SA | Air cooling | 8 | 7 | 45 | 2980 | 380V50Hz | 255 | 1½″ | 1050 | 1550*950*1450 |
7.7 | 8 | |||||||||
7 | 10 | |||||||||
5.8 | 13 | |||||||||
SRC-75SA | Air cooling | 10.5 | 7 | 55 | 2980 | 380V50Hz | 268 | 2″ | 1250 | 1900*1240*1700 |
9.8 | 8 | |||||||||
8.7 | 10 | |||||||||
7.5 | 13 | |||||||||
SRC-90SA | Air cooling | 11.7 | 7 | 65 | 2980 | 380V50Hz | 268 | 2″ | 1530 | 1900*1240*1700 |
11.3 | 8 | |||||||||
9.5 | 10 | |||||||||
8.4 | 13 |
◆ Selection of volume flow rate
① When choosing the volume flow rate of air compressor, we should
first know the volume flow rate of all the gas-using equipment and
multiply the total flow rate by 1.2 (that is, to enlarge the 20%
margin).
② the new project can be selected according to the flow rate
provided by the design institute.
③ to understand the volume and flow parameters of the gas
consumption equipment for the gas supplier.
④ Air compressor station transformation can refer to the original
parameter value and the actual gas consumption.
Appropriate type selection is beneficial to users and air
compressor equipment. Too much waste of type selection and too
small type selection may cause the air compressor to be in a
long-term loading state or insufficient gas consumption or pressure
can’t be beaten up.