Product Description:
DC to AC Conversion in Solar Power Systems
Solar power systems generate DC power through photovoltaic panels, while household and industrial power systems typically use AC power. The inverter plays a crucial role by converting DC power into AC power to meet the needs of domestic and industrial power consumption. This conversion is essential to ensure that the energy produced by solar panels can be put to practical use.
Grid Connection and Power Injection
In addition to converting DC to AC power, inverters are also responsible for injecting the converted AC into the grid. This grid connection is essential to make the solar power system effective and practical. The inverter ensures that the solar power system is connected to the grid and is providing power injection, making it easier to use solar energy resources more efficiently.
Parallel and Series Connection
The inverter not only converts power but also connects DC power from multiple solar panels in parallel or series to improve power generation efficiency. By optimizing the way the panels are combined, the inverter can maximize the use of solar energy resources and improve the overall performance of the solar power system. This parallel and series connection helps to balance the output of each solar panel and make the system more responsive and efficient.
Monitoring and Protection
The inverter has the ability to monitor the output power of the solar panels and regulate their output voltage and frequency to ensure high efficiency and safety of the system. The inverter also has a protection function, which can cut off the power supply in time in case of grid failure or abnormal situation to protect the solar power generation system from damage.
Applications:
The On Grid Inverter is an integrated grid inverter, designed to work in parallel with the grid, providing stable power to homes, businesses, and industries. This grid-interfacing inverter is ideal for those who want to reduce their dependence on grid power and save on electricity bills.
The On Grid Inverter is a grid-connected power inverter that is easy to install and operate. It comes with a user-friendly interface that allows users to monitor the performance of the inverter and adjust its settings accordingly. The inverter also comes with a range of safety features, ensuring that it operates safely and efficiently.
The On Grid Inverter is suitable for a range of applications and scenarios, including residential, commercial, and industrial settings. It is ideal for homes and businesses that want to reduce their carbon footprint and save on electricity bills. The On Grid Inverter is also suitable for industries that require a stable and reliable power supply.
The On Grid Inverter has an input voltage of 220V and produces a pure sine wave output waveform. It has an output voltage of 220V and a power output of 2KW. The efficiency of the On Grid Inverter is 95%, ensuring that it operates efficiently and effectively.
The minimum order quantity for the On Grid Inverter is 1 set, and the price is negotiable. The packaging details include foam and a plywooden case, ensuring that the product is protected during shipping. The delivery time for the product is 25 working days, and the payment terms include T/T, Western Union, MoneyGram, and L/C. The supply ability of the product is high, ensuring that customers can purchase the product as per their requirements.
MAC 15~36KTL3-XL
※ 3 MPPTS
※ 220V Three Phase Solution
※ Smart diagnosis
※ High efficiency up to 98.8%
※ Local WiFi configuration
※ OLED display and touch button
※ AC&DC type ll SPD
MID 6~12KTL3-XL
※ Max.efficiency98.5%
※ 40% compact andlighter
※ Dual MPp trackers
※ Supports export control
※ Touch key and OLED display
※ Type ll SPD on AC and DC side
MAX 50~75KTL3-XL 2
※ 8 MPPTs y diseno sin fusibles ※ Escaneo y diagnóstico inteligente de l/V
※ Monitoreo inteligente de cadenas
※ SPD tipo ll de CA y CC
※ Protección lP66 y C5
MAX 50~80KTL3 LV
※ 6/7MPPTSSmart diagnosis ※ High efficiency up to 99% ※ Local WlFl connection ※ String monitoring ※ AC&DC type II SPD ※ AFCl protection ※ Data storage up to 25 years ※ DC side 2 in 1 connection enabled
MIN 7000~10000 TL-X
※ Maximum efficiency 98.1%2/3 MPP trackers
※ Type ll SPD on DC side
※ Supports export control
※ Touch key and OLED display
Datasheet | MID 6KTL3-XL | MID 8KTL3-XL | MID 10KTL3-XL | MID 11KTL3-XL | MID 12KTL3-XL |
Input Data | |
Max.DC power | 65000W | 10400W | 13000W | 13000W | 15600W |
Max.DC voltage | |
Initial voltage | |
MPPT voltage range | |
Nominal voltage | |
Max. input current per MPPT | |
Output (AC) | |
Rated AC output power | 6000W | 8000W | 10000W | 11000W | 12000W |
Max. AC apparent power | 6600VA | 8800VA | 11100VA | 12100VA | 13300VA |
Max. output current | 16.5A | 22.1A | 27.8A | 30.3A | 30.3A |
AC nominal voltage | |
AC grid frequency | |
Max.efficiency | |
Datasheet | MIN 7000TL-X(E) | MIN 8000TL-X(E) | MIN 9000TL-X | MIN 10000TL-X |
Input Data |
Max.DC power | 12000W | 12000W | 13500W | 15000W |
Max.DC voltage | |
Start voltage | |
MPPT voltage range | |
Nominal voltage | |
Max. input current per MPPT | |
Output (AC) |
Rated AC output power | 7000W | 8000W | 9000W | 10000W |
Max. AC apparent power | 7000VA | 8000VA | 9000VA | 10000VA |
Max. output current | 33.5A | 33.5A | 43A | 45.5A |
Nominal AC voltage(range*) | Default:240V split-phase, optional:208V & 240V single phase , 183-228@208V 211-264V@240V |
AC grid frequency(range*) | 50/60 Hz (45-55Hz/55-65 Hz) |
Max.efficiency | |
Datasheet | MAC 15KTL3-XL | MAC 20KTL3-XL | MAC 22KTL3-XL | MAC 25KTL3-XL | MAC 30KTL3-XL | MAC 36KTL3-XL |
Input Data | | |
Max. recommended PV power (for module STC) | 22500W | 30000W | 33000W | 37500W | 45000W | 54000W |
Max.DC voltage | |
Initial voltage | |
MPPT voltage range | |
Nominal voltage | |
Max. input current per MPPT | |
Output (AC) |
Rated AC output power | 15000W | 20000W | 22000W | 25000W | 30000W | 36000W |
Max. AC apparent power | 16600VA@220VAC | 22200VA@220VAC | 24400VA@220VAC | 27800VA@220VAC | 33300VA@220VAC | 36000VA@220VAC 39200VA@240VAC |
Max. output current | 43.6A | 58.3A | 64.0A | 73.0A | 87.4A | 94.5A |
Nominal AC voltage(range*) | |
AC grid frequency(range*) | |
Max.efficiency | |
Hoja de datos | MAX 50KTL3-XL2 | MAX 60KTL3-XL2 | MAX 70KTL3-XL2 | MAX 75KTL3-XL2 |
Datos de entrada (CD) |
Max.DC power | 100000W | 120000W | 105000W | 112500W |
Rango de potencia máxima* | |
Voltaje de arranque | |
Voltaje nominal | |
Rango de voltaje de MPPT | |
Máxima corriente por MPPT | |
Salida (CA) |
Potencia nominal CA | 50000W | 60000W | 70000W | 75000W |
Potencia aparente máxima | 55500VA | 66600VA | 66000VA @208V 70000VA @220V 73000VA @230V | 71000VA @208V 75000VA @220V 78400VA @230V |
Voltaje nominal CA (Rango*) | |
Voltaje nominal CA (Rango*) | |
Frecuencia de red CA (Rango*) | 50/60Hz (45~55Hz/55-65 Hz) |
Máxima eficiencia | |
Datasheet | MAX 50KTL3 LV | MAX 60KTL3 LV | MAX 70KTL3 LV | MAX 80KTL3 LV |
Input Data |
Max.DC power | 65000W | 78000W | 91000W | 104000W |
Max.DC voltage | 1100V | 1100V | 1100V | 1100V |
Start voltage | |
MPPT voltage range | |
Nominal voltage | 585V | 585V | 600V | 600V |
Max. input current per MPPT | |
Output (AC) |
Rated AC output power | 50000W | 60000W | 70000W | 80000W |
Max. AC apparent power | 55500VA | 66600VA | 77700VA | 88800VA |
Max. output current | 80.5A | 96.6A | 112.7A | 128.8A |
AC nominal voltage | |
AC grid frequency | |
Max.efficiency | 98.8% | 98.8% | 99.9% | 99.9% |