Add to Cart
0.6/1kv xlpe covered overhead insulated cable 3x50+NA1x54.6 NFC33209 aerial bundled cable
Conductor:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel
Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.
Insulation: PVC, XLPE, PE
Standards:
GB/T 12527-2008, IEC60502-1, IS:14255-1995
Rated voltage: 0.6/1kV
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232,
BS215, DIN48201, DIN48204.
We can also manufacture ABC cable according to customer's special
requirements.
Application:
APPLICATION: Used primarily for overhead secondary distribution lines.
Below construction are also commonly used around the world.
A) Duplex Service Drop
Applications:To supply 120 volt aerial service for temporary
service at construction sites,outdoor or street lighting . For
service at 600 volts or lower at a conductor temperature of 75
maximum.
B) Triplex Service Drop
Applications: To supply power from the ulility`s lines to the
consumer`s weatherhead. For service at 600 volts or less(phase to
phase ) at a conductor temperature of 75 maximum for PE insulation
or 90 maximum for XLPE insulation .
3 cores consisting of standard aluminium conductors, insulated with
XLPE insulation
+ One sheath lighting aluminium conductor with XLPE
insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
It meets or exceeds the following specifications:
C ) Quadruplex Service Drop
Applications: Used to supply 3 phase power , usually from a
pole-mounted transformer to the use`s servic head where connection
to the service entance cable is made . To be used at voltages of
600 volts or less phase to phase and at conductor temperature not
to exceed 75 for PE insulated conductors or 90 for XLPE insulated
conductors.
0.6/1kv xlpe covered overhead insulated cable 3x50+NA1x54.6 NFC33209 aerial bundled cable parameters
NUMBER OF CORES X NOMINAL CROSS SECTION | OVERAL DIAMETER | WEIGHT | MAXIMUM CONDUCTOR RESISTANCE | MINIMUM BREAKING LOAD | CURRENT RATING |
NO.×MM² | MM | KG/KM | Ω/KM | KN | A |
2x10 RM | 12.8 | 93 | 3.080 | 1.5 | 38 |
4x10 RM | 15.4 | 183 | 3.080 | 1.5 | 38 |
2x16 RM | 14.8 | 129 | 1.910 | 2.3 | 72 |
4x16 RM | 17.8 | 257 | 1.910 | 2.3 | 72 |
2x25 RM | 18.0 | 202 | 1.200 | 3.8 | 107 |
4x25 RM | 21.7 | 404 | 1.200 | 3.8 | 107 |
2x35 RM | 20.8 | 269 | 0.868 | 5.2 | 132 |
4x35 RM | 25.1 | 539 | 0.868 | 5.2 | 132 |
2x50 RM | 23.4 | 352 | 0.641 | 7.6 | 165 |
1x54.6 RM + 3x25 RM | 21.7 | 507 | 0.630/1.200 | 3.8 | 107 |
1x54.6 RM + 3x25 RM + 1x16 RM | 24.3 | 573 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1x54.6 RM + 3x25 RM + 2x16 RM | 29.7 | 639 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1x54.6 RM + 3x25 RM + 3x16 RM | 31.1 | 705 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1x54.6 RM + 3x35 RM | 25.1 | 615 | 0.630/0.868 | 5.2 | 132 |
1x54.6 RM + 3x35 RM + 1x16 RM | 28.1 | 680 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1x54.6 RM + 3x35 RM + 2x16 RM | 34.3 | 748 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1x54.6 RM + 3x35 RM + 3x16 RM | 35.9 | 814 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1x54.6 RM + 3x35 RM + 1x25 RM | 28.1 | 714 | 0.630/0.868/1.200 | 5.2/3.8 | 132/107 |
1x54.6 RM + 3x50 RM | 28.2 | 741 | 0.630/0.641 | 7.6 | 165 |
1x54.6 RM + 3x50 RM + 1x16 RM | 31.6 | 806 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1x54.6 RM + 3x50 RM + 2x16 RM | 38.6 | 875 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1x54.6 RM + 3x50 RM + 3x16 RM | 40.4 | 940 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1x54.6 RM + 3x50 RM + 1x25 RM | 31.6 | 841 | 0.630/0.641/1.200 | 7.6/3.8 | 165/107 |
1x54.6 RM + 3x70 RM | 33.0 | 950 | 0.630/0.443 | 10.2 | 205 |
1x54.6 RM + 3x70 RM + 1x16 RM | 37.0 | 1014 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1x54.6 RM + 3x70 RM + 2x16 RM | 45.2 | 1083 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1x54.6 RM + 3x70 RM + 3x16 RM | 47.3 | 1148 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1x54.6 RM + 3x70 RM + 1x25 RM | 37.0 | 1048 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1x54.6 RM + 3x70 RM + 2x25 RM | 45.2 | 1150 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1x54.6 RM + 3x70 RM + 3x25 RM | 47.3 | 1250 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1x54.6 RM + 3x95 RM | 37.4 | 1176 | 0.630/0.320 | 13.5 | 240 |
1x54.6 RM + 3x95 RM + 1x16 RM | 41.9 | 1243 | 0.630/0.320/1.910 | 13.5/2.3 | 240/72 |
Other cross-sections can be offered upon request.
0.6/1kv xlpe covered overhead insulated cable 3x50+NA1x54.6 NFC33209 aerial bundled cable images
About Zhenglan Cable Technology Co., Ltd
Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.
FAQ
Is your company a factory or a trade company?
Factory, more than 20 years in China
How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the
samples will be ready for delivery in 3-7 days. The samples will be
sent to you via express and arrive in 3~7 days. You can use your
own express account or prepay us if you do not have an account.
What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as
the main payment terms, and other payment can also be negotiated.
Trade assurance on is also available.
What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity.
Usually it needs 7-30 days after get your payment.
What is your MOQ?
Generally it is 5000m.