M4 / B2 Hole Electric High Speed Handpiece Ceramic Bearing Torque Head
Description:
High Speed Dental Handpiece:M4/B2
Bur Applicable:Φ1.595-1.600mm
Product Parts:
Consists of handpiece head, handle, caudal thread, cartridge.
Working Conditions:
1. Air pressure 0.25~0.30mpa,must be filtrated.
2. Use high speed dental bur with shaft diameter
Φ1.59~1.60mm×21-23mm and roghtness less than 0.8um.
3. The amount of handpieces spray or water spray should be able to
adjusted.
4. Hard glass fiber,can be repeatedly sterilized in high
temperautre and pressure.
Product Scope:
Only used for drilling, molar of stomatology clamping high-speed
dental burs.
HPA010 Handpiece we Provide Three Kind Of Head For Choice
HPA010M | HPA010S | HPA010T |
Mini Head | Standard Head | Torque Head |
dental handpiece advantage:
1: Mini( Standard /Torgue Head.
2: The machine maintenance is simple ,can be more than stopwatch
used alternately to extend service life.
3: Hanpieces for single water spray ,drainage holes and air flow
adopts precision edm.
The atomization effect is better .
4: Classic non-slip pattern , feel more comfortable.
5: The collet type movement compared with opne movement
more can guarantee the movemnt up and down bearing concentricity.
Maintenance:
1. Considering safety first, please be careful to use it with full
attention.
2. Be limited to dentists who held the dental treatment
qualifications.
3. Strictly forbid decomposition and reconstruction by
unauthorized.
4. Please run point testing on outside of patients oral beforehand.
If feel anomalies, please stop using immediately and contact with
our after-sales center.
5. When appears abnormal during using, please stop it immediately
and contact with our after-sales center.
6. It will cause a high noise using a center-vibration or bended
bur and a handpiece of which bearing has been worn, A long time in
this state will be harm to people’s hearing. Forbid using a
vibration or bended bur, if appear high noise, please replace the
shaft core early
7. Do not use a bending , cracking, deformation and unqualified
bur. If using it, may cause a snap, or a flying off to injury
accident during operation process.
8. Please ensure the bur chuck be clean. If with contaminant inside
of it, may causes bur clamping weaken or shaft core vibration.
9. Please run the bur under the provision rotation-speed by bur
manufacturers.
10. Do not crash, especially to avoid falling.
11. Please install a bur or a standard stick before using.
12. Aslo remember to install a bur or a standard stick when not in
using.
13. Please unload the bur and handpiece when the running stopped in
completely.