Implant High Efficiency Low Speed Dental Handpiece , Dental Drill Handpiece


Description:

Professionally used by dentists as oral operative surgery tools for dental implant.
The product is available for dental motor implant system in accordance with ISO standard only.
Button type chuck.
Internal and external irrigation system.
Provides sufficient force at low speedMax torque 55N.cm
Ergonomic comfort grip.
20:1 gear ratio.
Reasonable price and excellent performance.
This handpiece is compatible with all e-type motors.


Contra angle handpiece
1) Low Speed 22,000-27,000 rpm.
2) The shank of the instrument mounted therein is 2.35 mm
3) Fastening of the instruments with a turning latch·
4) 135°C Autoclavable·
5) For any lab or E-type motors·
6) have two type for the client select: push button & wrench


Straight handpiece
1) Working pressure: 0.3MPa (4-hole);
2) 0.25MPa (2-hole) (Measure meter is installed at the end of air motor to measure the air pressure).
3) Revolution: about 22000-27000r/min (adjustable between clockwise or anticlockwise)
4) Noise: ≤68dB
5) Air consumption: about 56L/min
6) Ratio: 1:1
7) Max speed of contra angle: 25000rpm/min.


Air Motor
1) Supply air pressure: 245-392KPa (2.5-4kgf/CM2)
2) 1:1 Direct Drive
3) Midwest 4 holes
4) Max speed 20,000 min-1


Maintenance:
1. Considering safety first, please be careful to use it with full attention.
2. Be limited to dentists who held the dental treatment qualifications.
3. Strictly forbid decomposition and reconstruction by unauthorized.
4. Please run point testing on outside of patients oral beforehand. If feel anomalies, please stop using immediately and contact with our after-sales center.
5. When appears abnormal during using, please stop it immediately and contact with our after-sales center.
6. It will cause a high noise using a center-vibration or bended bur and a handpiece of which bearing has been worn, A long time in this state will be harm to people’s hearing. Forbid using a vibration or bended bur, if appear high noise, please replace the shaft core early


Our Services
* Quick response:Your inquire or message will be replied promptly;
* High quality:Quality is our first pursuit,the product you buy is same as description,your product will be strict quality control from material,producing,inspection and packing;
* Fast shipping:Your products will be shiped in time as contract by DHL/UPS/FEDEX/TNT or by sea;
* After sale service:Our sales will update you about shipping,deliverying,also follow the installation,make sure the product works well;Will also supply fast solution if any problem.


China Implant High Efficiency Low Speed Dental Handpiece , Dental Drill Handpiece supplier

Implant High Efficiency Low Speed Dental Handpiece , Dental Drill Handpiece

Inquiry Cart 0