Sistema De Filtro De Agua Planta De Osmosis Inversa Maquina
Comercial De Agua Potable
Water Filter System Reverse Osmosis Plant Commercial Drinking Water
Machine
RO Water Treatment System Description
Reverse osmosis is capable of removing 97-99% of total dissolved
solids (TDS), 99% of organic, including pyrogens, and 99% of all
bacteria in the feed water.
The pretreatment steps of water treatment equipment using quartz sand filter, activated carbon filter,
the softening system (optional) and the precise filter, the main
purpose is to remove the suspended solids in raw water,
including sediment particles ,organic colloids,organic matter,odor,chlorine
and other impurities.
Then the water enter the Reverse Osmosis system,
most of the dissolved salts, bacteria, hot stream will be filtered out, to ensure production water quality meet thestandards.
All of our pure water equipment are designed according to the customer’s raw water analysis, capacity and
product water requirements.
RO Water Treatment System Details
Ro system technical parameters(for raw/well feed water TDS max
20000ppm) |
Item Name | Brand | Material | Function |
Raw Water Pump | CNP/Grundfos/Danfoss | SUS-304/316 | Provide pressure for filters |
Quartz Sand Filter | KaiYuan | FRP/ Ss-304/316 | Filtrate sediments... |
Activated Carbon Filter | KaiYuan | FRP/ Ss-304/316 | Obsorb odor, smell, color, irons, chlorine... to make clear water |
Anti-scalant chemical dosing system/Water Softener | SEKO | | Soften water, protect RO Membranes |
Security filter | KaiYuan | FRP/ Ss-304/316 | Remove colloids larger than 5micro |
High pressure pump | CNP/Grundfos/Danfoss | SUS-304/316 | Provide pressure for Ro membranes |
RO vessels &membranes | Domestic&DOW/Toray/Votron/Hydrau. | FRP/Ss-304/316 | Remove dissolved ions,organic materia,bateria... |
Solenoid valves, gauges,switch... | China | Cooper/Ss-304/316 | To protect the machine underoperation |
CIP Washing system(optional) | KaiYuan | Ss-304/ FRP/316 | Membranes maitenance |
Electronic control | PLC Program control system | Water quality detector,AC contacter,Air switch,indicator light,knob
switch,electrical miscellaneous pieces... |
UV/Ozone(optional) | USA/Dahuang | Remove some baterial like coliform,pseudomonas
aeruginosa...(Sterilization) |
RO Water Treatment System Performance
⇒ Main part (membrane) of reverse osmosis system is imported from
USA.
⇒ Auto stop when no water and full water.
⇒ Auto controller, RO membrane auto flush to protect membrane.
⇒ Auto start when pure water tank have no water.
⇒ Low pressure protection switch to protect high pressure pump when
there is no raw water.
⇒ High efficient and low noise high pressure pump.
⇒ Product water conductivity meter to monitor product water quality
all the time.
⇒ Input water and output water pressure gauge to monitor RO
membrane *differential pressure to remind it's time for chemical
cleaning.
⇒ Inlet water solenoid valve to stop water when machine is stop.
RO Water Treatment System Features
1.Can run and produce water continuously, highly automatic
2.No need chemical to regeneration,easy operation and maintainance
3.RO system uses imported USA DOW membrane
4.Automatic switch on when lack of water,and switch off when no
water or full of water
5.RO membrane auto wash and reduce the pollution speed.
6.Low-pressure switch protects high-pressure pump from damage cause
by water supply stops.
7.Production water conductivity meter monitors water quality online
contionuosly.8.Input water and dense water pressure meters, monitor the RO
differential pressure and remind the time of washing.
RO Water Treatment System Processing
Process: raw water tank + raw water pump + quartz sand filter +
activated carbon filter + water softener/chemical dosing
system(optional) + security filter + high pressure pump + ro system
+ pure water tank + UV sterilizer(ozone generator) + precision
filter + water supply point
Some parts function:
1. Raw water pump: provide needed pressure for every pre-treatment
filter;
2. Quartz sand filter: use fiber glass as housing, fill quartz
sand, it can filter big particles impurities, suspended substances,
colloids etc. Important to remove iron and sediments you
mentioned;^^
3. Activated carbon filter: use fiber glass as housing, fill
activated carbon, remove color, odor, residual chlorine and
organics substances;
4. Security filter: prevent large particles, bacteria, viruses into
RO membrane, accuracy is 5µm;
5. High pressure pump: provide needed working pressure for RO
system, ensure production capacity of pure water;
6. RO system: can remove particles, colloids, organic impurities,
heavy metal ions, bacteria, virus, heat source etc. harmful
substances and 99% dissolved salts.
7. Ozone generator(for bottled drinking): can continue to kill
bacteria even water fill into bottled,viruses,cell damage,atc...
RO Water Treatment System Show
Feedback From Client
Thank you so much for your value time. Any questions please send us
inquiry or chat now!
We will reply you within 24hours. Whatsapp/ wechat/ tell: +86
13711203110
Guidelines for getting a proper quotation
Tell us the raw water/source of water
Provide water analysis report
Required production capacity( 500 liters per hour, 1000liters per
hour…)
What's the pure water used for( drinking, bottle water or
industrial use…)