Add to Cart
DC Power source Electrolysis Seawater Chlorine power supply 300a 18V
Description of high frequency electrolytic power supply:
In chemistry, electrolysis is a method of separating bonded elements and compounds by passing an electric current through them. An ionic compound, in this case salt, is dissolved with an appropriate solvent, such as water, so that its ions are available in the liquid. An electrical current is applied between a pair of inert electrodes immersed in the liquid. The negatively charged electrode is called the cathode, and the positively charged one the anode. Each electrode attracts ions which are of the opposite charge. Therefore, positively charged ions (called cations) move towards the cathode, while negatively charged ions (termed anions) move toward the anode. The energy required to separate the ions, and cause them to gather at the respective electrodes, is provided by an electrical power supply. At the probes, electrons are absorbed or released by the ions, forming a collection of the desired element or compound. .
Specification
SPECIFICATIONS FOR GKD18-300CVC | |||
Input AC | 380V±10% | 1phase | 50/60Hz |
Output DC | Volt | 0~18V Adjustable | |
Current | 0~300A Adjustable | ||
Power | 5.4KW | ||
Efficiency | >85% | ||
output Frequency | 40KHz fixed | ||
Protection | Short circuit protection Overheating protection Phase lack protection Input over/low voltage protection | ||
Working Condition (Temperature) | -10℃~50℃ | Control mode | Panel control Remote control |
Net weight | 18kg | Working mode | Constant Voltage(CV) Constant Current(CC) |
Dimension(mm) | 650*470*200mm | Cooling way | water cooling |
How to install rectifier
This is installation way for remote control rectifier. Not only
this way.
1. To connect copper bar with bath/tank
2. To ensure power supply/rectifier is grounded
3. To ensure there is enough water for water cooling type power
supply/rectifier
4. We advice that all rectifiers should be isolated to increase of
its life.
Feature:
1. Display: LED display of output voltage and current (D LCD
display can be added according to customer requirements);
2. Appearance: desktop, tower or 19-inch standardized size, can be
combined and placed on various work surfaces and racks;
3. Advantages: High frequency PWM hardware adjustment soft switch
control technology makes the power supply high efficiency, low
ripple, low noise, high reliability, small size and light weight;
4. Constant voltage and constant current: The output CC/CV constant
voltage and constant current are automatically switched, and the
voltage and current values are continuously and linearly adjusted
from zero to the rated value;
5. Protection function: over-voltage protection (OVP), over-current
protection (OCP), over-temperature protection (OTP), under-voltage
protection, overload protection;
6. Short-circuit characteristics: it can be short-circuited for a
long time under working conditions;
7. External compensation: Optional external compensation (Remote
Sensing) can be used to reduce loop cable voltage drop;
8. Overvoltage protection value: The output overvoltage protection
value is adjustable, after protection, the output is cut off and
locked, and restarted to restore;
9. Current preset function: The user can preset any current
actually required by the load without connecting the load. When the
product actually has current output, the actual output of a large
current can reach the preset value (optional) .
10. Voltage preset function: The user can preset any voltage
actually required by the load without output voltage. When the
product actually has voltage output, the actual output larger
voltage can reach the preset value. (Optional)
11. Overvoltage preset function: The overvoltage protection value
of the power supply can be preset on the panel, that is, press and
hold the overvoltage preset button on the panel, adjust the
overvoltage potentiometer, and you can get the actual required
overvoltage protection value. (Optional)
12. Computer program control function: optional
RS485/RS232/GPIB/LAN/CAN and other data interfaces, standard Modbus
or Can2.0 communication protocol, and computer/host computer
software control and monitoring can be configured. It can be
controlled by multiple sets of network, and master-slave parallel
control. (Optional)
13. PLC remote sampling: optional (isolated/non-isolated) 0-5V,
0-10V, 4-20mA and other PLC analog signals to control the voltage
and current control of the power supply and feedback; switch signal
and high and low level signal switching machine; ( (Optional)
14. Programming and storage function: 30 sets of different voltage,
current, delay time and running time can be set at a time, and can
be cycled 999999 times; 10 sets of memory group parameters are
stored for easy recall. (Optional)
15. Timing function: optional timing switch function, timing
operation or cycle permission; (optional)
16. Positive and negative commutation function: can provide output
positive and negative commutation function (bipolar), commutation
mode: manual, timing, computer program control, etc. (optional)
17. Pulse function: add a chopper circuit to the basic circuit of
the conventional DC power supply to realize the independent
adjustment of voltage, current, frequency and duty ratio; single
pulse, periodic commutation pulse, positive and negative double
pulse, etc. (optional)
18. Installed ampere meter: larger setting range 1-9999999 ampere
minutes (if you want to divide the set value by 60 in ampere
hours); the cumulative (AH) display value is the cumulative value
from the factory to the time of viewing .