LK-C65B HDR-600 CE FDA Approved RVG Dental XRay Sensor 32.3*44.3mm
Twain Driver
The Digital dental X-ray imaging system is intended to generate
intraoral x-ray
image ,require to working with x-ray source and imaging software in
dental clinic for
dentist and orthodontists.
Packinglist
Manual | 1pc |
CD | 1pc |
X-Ray Sensor with controller | 1pc |
Holder | 1pc |
Sleeves | 1 bag |
Safety Classifications
Safety Type: Class-Ⅱ BF
Power: DC5V Maximum 600MA.Rate of Work: Max 1W
Degree of protection against ingress of water: IPX7
Non AP equipment, non APG equipment
Mode of operation: Continuous operation
Operating conditions
Environment Temperature | +10℃~+40℃ |
Environment relative humidity | ≤95% |
Air pressure | 860hPa~1060hPa |
Transport and Storage conditions
Environment Temperature | -25℃~+60℃ |
Environment relative humidity | 10%~93% |
Air pressure | 860hPa~1060hPa
|
Protect Sensor from Potential ESD Damage
Like other electronic devices, Sensor is susceptible to
electrostatic discharge (ESD),
particularly when the device is used in or around carpeted areas or
low humidity
environments. During cable replacement, when Sensor contacts are
exposed, it is
especially important to protect the device from potential ESD
damage. Touching a
metal surface prior to replacing the cable will reduce the risk of
damaging Sensor
components by accidental static discharge. The use of anti-static
floor mats or floor
treatments (for example Staticide 6005/6002) will also help
eliminate static build-up
in your office.
Do Not Touch Exposed Connectors on Non-Medical
Equipment and the Patient at the Same Time
When the Sensor and controller are in use, avoid touching exposed
connectors on
non-medical electrical equipment and the patient at the same time.
The human body is
capable of conducting electrical current and may cause a shock
hazard to patients if
appropriate safety practices are not observed
Ensure Proper System and PC Workstation
Installation and Operation
The Sensor and controller have been determined to be in accordance
with
international safety standards and are deemed suitable for use
within the patient area,
which extends from the patient for a distance of 5 ft (1.5m). To
comply with these
standards, do not operate non-medical equipment (such as a PC
workstation) inside
the patient area. Outside the patient area, the presence of
approved non-medical grade
equipment and Listed / Approved / IEC 60950-1 certified Information
Technology
Equipment (ITE) computer equipment is acceptable. The host computer
(PC
3workstation) should be CE-approved and conform to the Low
Voltage [73/23/EC] and EMC Directive [89/336/ERC]. The system shall
be in
accordance with IEC60601-1-1. The person connect the product
to the host computer shall insure its compliance. Also, to help
ensure optimal
performance, ensure that all software programs residing on the
workstation are
virus-free and have been adequately tested so they will not impact
imaging
applications after installation. Any questions please contact your
local distributor
Besides, we have some other related dental items:X ray sensor,
portable X ray unit and X ray scanner etc