L(W)DR series small electric automatic heating steam boiler with
quick starting Preparation before use
Preparation before use
Electric heating steam boiler Product advantages:
1. Convenience.
After the power supply is introduced into the electric control box,
the boiler will enter (or leave) the automatic operation state with
one key operation.
2. Automatic water injection.
The amount of water in the boiler is reduced, and the control
system automatically replenishes the water from the tank to the
boiler through a supplementary pump.
3. Save energy.
In order to use electric energy reasonably and effectively, the
heating power is divided into several stages and controlled by the
controller automatically.
The user needs to determine the heating power, just close the
corresponding leakage circuit breaker.
At the same time, the segmented circulation of the heating pipe
reduces the impact of the boiler on the power grid in operation.
3. Reliability.
The boiler body USES argon arc welding primer, manual welding cover
surface, after X-ray inspection of the strict inspection.
4. Strict material selection.
The steel used in the electric heating steam boiler is strictly
selected according to the manufacturing standard.
Boiler accessories are selected high-quality products, and through
the test furnace inspection, ensure the quality of the boiler, can
effectively improve the boiler operating instructions.
Preparation before use
1. The operator must understand the working principle, position,
performance and working method of various auxiliary parts of the
boiler.
2. Check the installation of combustion oil, wiring and pipe
nozzles, power supply, burner, water pump and boiler accessories.
3. After determining the opening and closing state of the main gas
valve, close the main gas valve.
4. Check the water level meter to make sure that it rises and falls
flexibly and is in a normal position.
5. Set the pressure regulator correctly and adjust the combustion
damper.
Maintenance:
1. maintenance of the boiler, must cut off the power supply while
reducing the pressure inside the boiler.
2. The burner should be removed from the boiler body every two
months to remove foreign matters such as carbon accumulation and
dust inside.
The photoelectric tube is polished once a month, the fuel filter
should always keep clean to ensure its filtering function.
Special attention should be paid to cleaning the oil pump filter
net, do not destroy the gasket.
The burner must not idle without oil to avoid damage to the oil
pump.
3. Keep the water level meter clean at all times. Open the cleaning
valve and rinse it once a day to ensure the clear calibration of
the water level meter.
4. The safety valve is pulled once a day to prevent rust failure.
Electric Heating Steam Boiler data sheet as follows (for reference
only) :
WDR Series Electric Heating Steam Boiler - Technical Parameter | ||||||||
Model | WDR0.75-1.0 | WDR1-1.0 | WDR1.5-1.0 | WDR2-1.0 | WDR3-1.0 | WDR4-1.25 | ||
Project | unit | |||||||
Rated evaporation | t/h | 0.75 | 1 | 1.5 | 2 | 3 | 4 | |
Fixed work stress | MPa | 1 | 1 | 1 | 1 | 1 | 1.25 | |
Saturated vapor temperature | °C | 184 | 184 | 184 | 184 | 184 | 193 | |
input power | KW | 540 | 720 | 1080 | 1440 | 2160 | 2880 | |
Input Current | A | 810 | 1080 | 1620 | 2160 | 3240 | 4320 | |
Rated voltage | V | 380 | ||||||
Power × number of groups | KW×P | 36×15 | 36×20 | 36×30 | 36×40 | 36×60 | 36×80 | |
a main steam valve caliber | DN | 40 | 40 | 65 | 65 | 80 | 100 | |
b safety valve caliber | DN | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | |
c inlet diameter | DN | 40 | 40 | 40 | 40 | 40 | 40 | |
d drain valve caliber | DN | 40 | 40 | 40 | 40 | 40 | 40 | |
Boiler dimensions | L | Mm | 2800 | 2950 | 3450 | 3500 | 3950 | 4100 |
L1 | Mm | 2400 | 2500 | 3050 | 2880 | 3200 | 3550 | |
W | Mm | 1800 | 1900 | 2180 | 2000 | 2100 | 2480 | |
W1 | Mm | 1550 | 1600 | 1430 | 1880 | 1980 | 2120 | |
H | Mm | 1550 | 1600 | 2100 | 2500 | 2650 | 2980 | |
H1 | Mm | 1300 | 1350 | 1850 | 1900 | 2100 | 2200 | |
Control cabinet size | A long | Mm | 1200 | 1200 | 1500 | 1500 | 1800 | 2100 |
B wide | Mm | 500 | 600 | 600 | 600 | 600 | 600 | |
C high | Mm | 1800 | 800 | 2000 | 2000 | 2200 | 2200 | |
weight | Kg | 2300 | 2850 | 3220 | 3550 | 4100 | 5200 |