Dependable Performance 700kw gas fired hot water heater Instant Induction Hot Water Boiler Heaters
Gas fired hot water heater features
The working atmospheric hot water boiler heating system relies on
the flow resistance and pressure values. The use of hot water
boilers for heating energy-saving effect is more obvious, the
boiler is not allowed to have any part of vaporization, the boiler
water capacity is small, in the case of sudden power failure
operation, water vapor is easy to cook, water hammer may be
generated.
1, boiler working pressure
The working atmospheric hot water boiler heating system relies on
the flow resistance and pressure values. The working pressure of
the hot water boiler, the nameplate only gives the force to make
the pressure of the boiler, but in actual operation, the boiler
pressure tends to be lower than this value. Therefore, the safety
margin of hot water boilers is relatively large.
2, with smoke and a pot of water, small scale large temperature difference, so that good heat
transfer efficiency is higher.
3. The energy-saving effect of using hot water boilers for heating is more obvious. There is no hot water heating boiler steam heating steam loss, the loss is also greatly reduced, the sewage treatment system and traps have greatly reduced leakage, and heat loss is also reduced. Therefore, it can save 20% of fuel compared to steam hot water heating system heating system.
4. The boiler is not allowed to have any part of vaporization, otherwise it will destroy the circulation of water.
5, no oxygen water, oxygen corrosion is prominent; tail heating surface temperature acid corrosion tendency.
6. From the operation of the precipitating water dissolved gas
boiler, structural problems need to consider the elimination of
gas.
The Gas fired hot water heater we usually refer to is an atmospheric hot water boiler. The atmospheric hot water boiler is not subject to conditions and there are no safety hazards. Nowadays, people choose heating, bathing and hot water for atmospheric hot water boilers.
Boiler and hot water heater requirements
The design, manufacture and inspection of the boiler shall comply
with the requirements of the "Safety Technical Supervision
Regulations for Hot Water Boilers".
The boiler should have modern technology, long-term operation
output, less air leakage, high thermal efficiency, low water
resistance, low power consumption, and low operating costs. The
boiler and its supporting equipment should be brand new, reliable,
technologically advanced and mature.
The boiler structure is reasonable and advanced, and can adapt to
load changes. It should be able to run smoothly within the load
range of 20% to 110%. The boiler has a fast heating rate, meets the
requirements of fast start-stop, fast operation, convenient
maintenance and stable performance.
Gas fired hot water heater Technical performance requirements
1, Boiler body
1.The welds of the pipes of each heating surface of the boiler
shall be subjected to 100% non-destructive inspection and shall
have the inspection certificate. Strict inspection should be
carried out before leaving the factory, and no foreign matter or
welding slag is allowed to remain in the pipe and in the header.
2.The design and manufacture of each component must comply with the
regulations issued by the state. Welding of dissimilar steels with
large differences in alloying elements in the heating surface of
the boiler should generally be completed in the manufacturing plant
and should have welding records (including pre-weld preheating,
welding methods, joint types, welding rods, post-weld heat
treatment, etc.). ).
2,Water supply tank: The boiler should be provided with automatic water supply function. And the water tank should be equipped with a water tank cover. The tank should be installed with an overflow pipe in a location with drainage. After the water tank is installed, clean up the debris in the water tank.
3,Points, water collectors
The effective length of the water separator and the water collector
shall not be less than 800 mm, and φ shall not be less than 219 mm.
4, Chimney
Diameter: D219, length: 6 meters. Low temperature discharge is
required, and the exhaust gas temperature does not exceed 200
degrees.
5,Electrical and Control
1.The bidder shall provide the boiler electrical control cabinet,
including various electrical components and electrical wiring
devices, in the factory as required by this specification. The
electric wiring device and the electric motor control and
protection equipment of the electric control cabinet shall be
provided in complete. The selection of electrical components of the
electric control cabinet should be advanced and reliable. An
alternate fuse must be provided.
2.The electronic control system should have two sets of systems;
one is for the automatic system to operate separately, and the
other is for manual system operation, any type of damage can not
affect the other normal use.
Gas fired hot water heater 0.35MW-14MW Oil Gas Fired hot water boiler technical datasheet
Main technical parameters of CWNS oil (gas) atmospheric pressure and pressure hot water boiler | |||||||||||||||
Project model | CWNS, WNS series hot water boiler | ||||||||||||||
Rated calorific value (MW) | 0.35 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 8.4 | 10.5 | 12.6 | 14 | |
Working pressure (MPa) | Normal pressure / pressure | ||||||||||||||
Outlet water temperature (°C) | 85/115 | ||||||||||||||
Backwater temperature (°C) | 60/70 | ||||||||||||||
Boiler thermal efficiency (%) | 91—95 | ||||||||||||||
Feed water temperature (°C) | 20 | ||||||||||||||
Fuel consumption | Diesel (Kg/h) | 32 | 65.4 | 98 | 131 | 196.2 | 261.6 | 327 | 392.4 | 523.2 | 654 | 784.8 | 981 | 1177 | 1310 |
Heavy oil (Kg/h) | 34 | 69.5 | 105 | 139 | 208.5 | 278 | 347.5 | 417 | 556 | 695 | 864 | 1042.5 | 1251 | 1390 | |
Natural gas (m3/h) | 39.5 | 79.3 | 119 | 159 | 237.9 | 317.2 | 396.5 | 475.8 | 644 | 793 | 951.6 | 1189.5 | 1427.4 | 1586 | |
Liquefied gas (m3/h) | 14.2 | 29 | 43.5 | 58 | 87 | 116 | 145 | 174 | 232 | 290 | 348 | 435 | 522 | 580 | |
City gas (m3/h) | 84 | 168.5 | 253 | 337 | 505.5 | 674 | 842.5 | 1011 | 1348 | 1685 | 2022 | 2527.5 | 3033 | 3370 | |
Boiler transportation | Length (mm) | 2800 | 3500 | 4100 | 4500 | 4700 | 4550 | 5700 | 6300 | 7000 | 7200 | 7840 | 8100 | 8230 | 8250 |
Width (mm) | 1600 | 1600 | 1900 | 2000 | 2110 | 2210 | 2500 | 2600 | 2700 | 2800 | 2860 | 3100 | 3100 | 3400 | |
High (mm) | 2000 | 2100 | 2310 | 2360 | 2470 | 2580 | 2800 | 2900 | 3200 | 3300 | 3300 | 3400 | 3400 | 3550 | |
Total power consumption (KW) | 2.3 | 6.7 | 11 | 13.5 | 19 | 21 | 23.5 | 26 | 37 | 37 | 42 | 45 | 52 | 52 | |
Chimney diameter (mm) | 250 | 350 | 430 | 450 | 450 | 550 | 650 | 650 | 650 | 800 | 800 | 900 | 1200 | 1200 | |
Shipping weight (T) | 3.2 | 4.7 | 4.8 | 5.4 | 8 | 9.78 | 13.4 | 15.4 | 17.4 | 17.4 | 23.8 | 30 | 31.6 | 34.5 | |
Heating area (m2) | 3000 | 6000 | 900 0 | 1200 0 | 1800 0 | 2400 0 | 3000 0 | 3600 0 | 4800 0 | 6000 0 | 7200 0 | 900 00 | 1080 00 | 1200 00 | |
Water supply capacity (t) | 7 | 15 | 22 | 30 | 45 | 60 | 75 | 90 | 120 | 150 | 180 | 225 | 270 | 300 |
Oil water boiler Vocume hot water boiler
Project / model | ZKW0.7-85/60-Y(Q) | ZKW1.05-85/60-Y(Q) | ZKW1.4-85/60-Y(Q) | ZKW1.75-85/60-Y(Q) | ZKW2.1-85/60-Y(Q) | ZKW2.8-85/60-Y(Q) | ZKW3.5-85/60-Y(Q) | |
Heat medium water capacity (L) | 410 | 520 | 568 | 700 | 830 | 980 | 1250 | |
Rated calorific value (Mw/h) | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | 3.5 | |
Rated calorific value | 60 | 90 | 120 | 150 | 180 | 240 | 300 | |
Fuel consumption | Light diesel oil (Kg/h) | 64 | 96 | 128 | 160 | 192 | 256 | 320 |
Heavy oil (Kg/h) | 67.3 | 100 | 134 | 168 | 202 | 269 | 363 | |
Natural gas (m3/h) | 165 | 116 | 155 | 193 | 232 | 310 | 387 | |
City gas (m3/h) | 77 | 247 | 330 | 412 | 494 | 659 | 824 | |
Liquefied gas (m3/h) | 29 | 44 | 58 | 73 | 88 | 117 | 146 | |
Heat Exchanger | Material/structure | Stainless steel | ||||||
Working pressure (MPa) | 1 | |||||||
Heating | Maximum calorific value | 36 | 54 | 72 | 90 | 108 | 144 | 180 |
Warm water circulation | 36 | 54 | 72 | 90 | 108 | 144 | 180 | |
Pressure loss | 2.2 | 3 | 2 | 2.6 | 2.5 | 3.5 | 3.3 | |
Heating outlet (DN) | 65 | 80 | 80 | 100 | 125 | 125 | 133 | |
Heating area (m2) | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 | |
Special for hot water | Maximum calorific value | twenty four | 36 | 48 | 60 | 72 | 96 | 120 |
Water supply capacity (m3/h) | 6 | 9 | 12 | 15 | 18 | twenty four | 30 | |
Hot water temperature | 50 | |||||||
Pressure loss | 2 | 0.6 | 1.5 | 1.8 | 1.5 | 1.8 | 2 | |
Water outlet diameter (DN) | 40 | 65 | 65 | 80 | 100 | 100 | 125 | |
Voltage | Voltage (V) | 220/380 | ||||||
Total power consumption | 2.2 (2.6) | 3.7 (4.1) | 5.0 (6.5) | 7.5(9) | 11 (2.5) | 15 (16.5) | 18.5(20) | |
Blower power consumption | 2.2 | 3.7 | 5 | 7.5 | 11 | 15 | 18.5 | |
Oil pump power consumption | 0.4 | 0.4 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | |
size | Chimney diameter (mm) | 350 | 350 | 400 | 450 | 500 | 550 | 600 |
Long (m) | 2700 | 3200 | 3400 | 4050 | 4700 | 4900 | 5500 | |
Width (m) | 1365 | 1365 | 1600 | 1600 | 1600 | 1800 | 2020 | |
High (m) | 2345 | 2400 | 2500 | 2580 | 2580 | 2630 | 2700 |