Forced hot water boiler Big Production Ability 2.1MW Fire Gasonline Hot Water Boiler
The Forced hot water boilerincludes an electric hot water boiler, a fuel hot water boiler, a gas hot water boiler, and a coal-fired hot water boiler. The hot water boiler is a boiler that produces hot water, and refers to heat energy or other heat energy (such as electric energy) released by combustion of the fuel. , solar energy, etc.) A thermal energy device that heats water to a rated temperature.
The Forced hot water boiler is divided into a normal pressure hot water boiler and a pressure hot water boiler. The atmospheric pressure hot water boiler belongs to a non-pressure civil life boiler, which is convenient, fast and safe to use, and does not need to be filed by the technical supervision department; the pressure hot water boiler is a pressure vessel. It belongs to special equipment. The design, manufacture, installation and use of pressure-bearing boilers are supervised by technical supervision departments and need to apply for boiler use certificates.
The Forced hot water boiler we usually refer to is an atmospheric hot water boiler. The atmospheric hot water boiler is not subject to conditions and there are no safety hazards. Nowadays, people choose heating, bathing and hot water for atmospheric hot water boilers.
Boiler and hot water heater requirements
The design, manufacture and inspection of the boiler shall comply
with the requirements of the "Safety Technical Supervision
Regulations for Hot Water Boilers".
The boiler should have modern technology, long-term operation
output, less air leakage, high thermal efficiency, low water
resistance, low power consumption, and low operating costs. The
boiler and its supporting equipment should be brand new, reliable,
technologically advanced and mature.
The boiler structure is reasonable and advanced, and can adapt to
load changes. It should be able to run smoothly within the load
range of 20% to 110%. The boiler has a fast heating rate, meets the
requirements of fast start-stop, fast operation, convenient
maintenance and stable performance.
Forced hot water boiler Technical performance requirements
1, Boiler body
1.The welds of the pipes of each heating surface of the boiler
shall be subjected to 100% non-destructive inspection and shall
have the inspection certificate. Strict inspection should be
carried out before leaving the factory, and no foreign matter or
welding slag is allowed to remain in the pipe and in the header.
2.The design and manufacture of each component must comply with the
regulations issued by the state. Welding of dissimilar steels with
large differences in alloying elements in the heating surface of
the boiler should generally be completed in the manufacturing plant
and should have welding records (including pre-weld preheating,
welding methods, joint types, welding rods, post-weld heat
treatment, etc.). ).
2,Water supply tank: The boiler should be provided with automatic water supply function. And the water tank should be equipped with a water tank cover. The tank should be installed with an overflow pipe in a location with drainage. After the water tank is installed, clean up the debris in the water tank.
3,Points, water collectors
The effective length of the water separator and the water collector
shall not be less than 800 mm, and φ shall not be less than 219 mm.
4, Chimney
Diameter: D219, length: 6 meters. Low temperature discharge is
required, and the exhaust gas temperature does not exceed 200
degrees.
5,Electrical and Control
1.The bidder shall provide the boiler electrical control cabinet,
including various electrical components and electrical wiring
devices, in the factory as required by this specification. The
electric wiring device and the electric motor control and
protection equipment of the electric control cabinet shall be
provided in complete. The selection of electrical components of the
electric control cabinet should be advanced and reliable. An
alternate fuse must be provided.
2.The electronic control system should have two sets of systems;
one is for the automatic system to operate separately, and the
other is for manual system operation, any type of damage can not
affect the other normal use.
Commerical hot water boiler Features:
1. Adopting the normal pressure mode, the boiler is not under
pressure, and the safety factor is high, and there is no danger of
explosion.
2. Designed as a burner-type pyrotechnic tube boiler, the fuel is
burned by the burner in a micro-positive pressure in the furnace,
the high-temperature flue gas is radiated and heat-exchanged in the
furnace, and then enters the convective heat exchange of the
pyrotechnic tube, and finally passes through the upper cigarette
case. discharge.
3. The boiler body design of the boiler body adopts computer
optimized simulation design, which fully optimizes the size of the
boiler and makes the shape harmonious and beautiful.
4. The flue pipe is inserted with a baffle to slow down the flue
gas discharge speed, strengthen the heat exchange, ensure the heat
generated by the fuel combustion to heat the boiler water to the
greatest extent, and greatly improve the thermal efficiency of the
boiler.
5, equipped with imported brand burners, fully automatic program
control, high degree of automation, the fuel system provides the
fuel needed for combustion, the air supply system sends the
appropriate wind speed, air volume, the ignition system ignites the
mixture of air and fuel, the detection system Ensure stable and
safe combustion of the burner
6. The gap between the large diameter pipe and the large hole
bridge makes the scale coating thin and easy to clean in the same
time. Product map
7, the shell shell furnace large interlayer water jacket, the
boiler water capacity is large, can provide sufficient boiling
water.
8, with multiple safety protection: leakage protection means that
leakage automatically cuts off the power supply; overheat
protection means that when the boiler water temperature reaches the
alarm temperature, the burner is automatically stopped and an alarm
is issued; when the secondary overheat protection means that the
temperature of the boiler casing exceeds 105 °C, it is
automatically cut off. The secondary circuit, the boiler stops
working; the water level detection protection uses the
sophisticated water level electrode rod to monitor the water level
in real time, and the water level is lower than the upper limit
water level solenoid valve until the upper limit water level is
reached.
9, mechatronics design, small size, easy to install and transport.
10. The furnace is specially treated to ensure the water quality is
clean and hygienic.
11, the outer lining aluminum foil glass wool for insulation,
better insulation effect.
12, white color plate packaging, beautiful, clean and rust
resistant.
13. The water supply port is at the lower part, the solenoid valve
automatically replenishes water, and the boiling water in the
boiling water area takes water to eliminate the phenomenon of “hot
and cold water” and “thousand boiling water” to ensure that 100% of
the drinking water is pure boiling water. 14. The boiler can be
used in two machines, which can supply boiling water and provide
hot water.
Oil water boiler 0.35MW-14MW Oil Gas Fired hot water boiler technical datasheet
Main technical parameters of CWNS oil (gas) atmospheric pressure and pressure hot water boiler | |||||||||||||||
Project model | CWNS, WNS series hot water boiler | ||||||||||||||
Rated calorific value (MW) | 0.35 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 8.4 | 10.5 | 12.6 | 14 | |
Working pressure (MPa) | Normal pressure / pressure | ||||||||||||||
Outlet water temperature (°C) | 85/115 | ||||||||||||||
Backwater temperature (°C) | 60/70 | ||||||||||||||
Boiler thermal efficiency (%) | 91—95 | ||||||||||||||
Feed water temperature (°C) | 20 | ||||||||||||||
Fuel consumption | Diesel (Kg/h) | 32 | 65.4 | 98 | 131 | 196.2 | 261.6 | 327 | 392.4 | 523.2 | 654 | 784.8 | 981 | 1177 | 1310 |
Heavy oil (Kg/h) | 34 | 69.5 | 105 | 139 | 208.5 | 278 | 347.5 | 417 | 556 | 695 | 864 | 1042.5 | 1251 | 1390 | |
Natural gas (m3/h) | 39.5 | 79.3 | 119 | 159 | 237.9 | 317.2 | 396.5 | 475.8 | 644 | 793 | 951.6 | 1189.5 | 1427.4 | 1586 | |
Liquefied gas (m3/h) | 14.2 | 29 | 43.5 | 58 | 87 | 116 | 145 | 174 | 232 | 290 | 348 | 435 | 522 | 580 | |
City gas (m3/h) | 84 | 168.5 | 253 | 337 | 505.5 | 674 | 842.5 | 1011 | 1348 | 1685 | 2022 | 2527.5 | 3033 | 3370 | |
Boiler transportation | Length (mm) | 2800 | 3500 | 4100 | 4500 | 4700 | 4550 | 5700 | 6300 | 7000 | 7200 | 7840 | 8100 | 8230 | 8250 |
Width (mm) | 1600 | 1600 | 1900 | 2000 | 2110 | 2210 | 2500 | 2600 | 2700 | 2800 | 2860 | 3100 | 3100 | 3400 | |
High (mm) | 2000 | 2100 | 2310 | 2360 | 2470 | 2580 | 2800 | 2900 | 3200 | 3300 | 3300 | 3400 | 3400 | 3550 | |
Total power consumption (KW) | 2.3 | 6.7 | 11 | 13.5 | 19 | 21 | 23.5 | 26 | 37 | 37 | 42 | 45 | 52 | 52 | |
Chimney diameter (mm) | 250 | 350 | 430 | 450 | 450 | 550 | 650 | 650 | 650 | 800 | 800 | 900 | 1200 | 1200 | |
Shipping weight (T) | 3.2 | 4.7 | 4.8 | 5.4 | 8 | 9.78 | 13.4 | 15.4 | 17.4 | 17.4 | 23.8 | 30 | 31.6 | 34.5 | |
Heating area (m2) | 3000 | 6000 | 900 0 | 1200 0 | 1800 0 | 2400 0 | 3000 0 | 3600 0 | 4800 0 | 6000 0 | 7200 0 | 900 00 | 1080 00 | 1200 00 | |
Water supply capacity (t) | 7 | 15 | 22 | 30 | 45 | 60 | 75 | 90 | 120 | 150 | 180 | 225 | 270 | 300 |
Oil water boiler Vocume hot water boiler
Project / model | ZKW0.7-85/60-Y(Q) | ZKW1.05-85/60-Y(Q) | ZKW1.4-85/60-Y(Q) | ZKW1.75-85/60-Y(Q) | ZKW2.1-85/60-Y(Q) | ZKW2.8-85/60-Y(Q) | ZKW3.5-85/60-Y(Q) | |
Heat medium water capacity (L) | 410 | 520 | 568 | 700 | 830 | 980 | 1250 | |
Rated calorific value (Mw/h) | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | 3.5 | |
Rated calorific value | 60 | 90 | 120 | 150 | 180 | 240 | 300 | |
Fuel consumption | Light diesel oil (Kg/h) | 64 | 96 | 128 | 160 | 192 | 256 | 320 |
Heavy oil (Kg/h) | 67.3 | 100 | 134 | 168 | 202 | 269 | 363 | |
Natural gas (m3/h) | 165 | 116 | 155 | 193 | 232 | 310 | 387 | |
City gas (m3/h) | 77 | 247 | 330 | 412 | 494 | 659 | 824 | |
Liquefied gas (m3/h) | 29 | 44 | 58 | 73 | 88 | 117 | 146 | |
Heat Exchanger | Material/structure | Stainless steel | ||||||
Working pressure (MPa) | 1 | |||||||
Heating | Maximum calorific value | 36 | 54 | 72 | 90 | 108 | 144 | 180 |
Warm water circulation | 36 | 54 | 72 | 90 | 108 | 144 | 180 | |
Pressure loss | 2.2 | 3 | 2 | 2.6 | 2.5 | 3.5 | 3.3 | |
Heating outlet (DN) | 65 | 80 | 80 | 100 | 125 | 125 | 133 | |
Heating area (m2) | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 | |
Special for hot water | Maximum calorific value | twenty four | 36 | 48 | 60 | 72 | 96 | 120 |
Water supply capacity (m3/h) | 6 | 9 | 12 | 15 | 18 | twenty four | 30 | |
Hot water temperature | 50 | |||||||
Pressure loss | 2 | 0.6 | 1.5 | 1.8 | 1.5 | 1.8 | 2 | |
Water outlet diameter (DN) | 40 | 65 | 65 | 80 | 100 | 100 | 125 | |
Voltage | Voltage (V) | 220/380 | ||||||
Total power consumption | 2.2 (2.6) | 3.7 (4.1) | 5.0 (6.5) | 7.5(9) | 11 (2.5) | 15 (16.5) | 18.5(20) | |
Blower power consumption | 2.2 | 3.7 | 5 | 7.5 | 11 | 15 | 18.5 | |
Oil pump power consumption | 0.4 | 0.4 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | |
size | Chimney diameter (mm) | 350 | 350 | 400 | 450 | 500 | 550 | 600 |
Long (m) | 2700 | 3200 | 3400 | 4050 | 4700 | 4900 | 5500 | |
Width (m) | 1365 | 1365 | 1600 | 1600 | 1600 | 1800 | 2020 | |
High (m) | 2345 | 2400 | 2500 | 2580 | 2580 | 2630 | 2700 |