Add to Cart
Natural gas burner for boiler industrial thermal oil heater gas burner curing furnace two stage modulated
YXG series small and medium two-stage Natural gas burner for boiler
Using natural gas (NG, LNG) and liquefied petroleum gas (LPG) as
fuel, fully automatic double-stage fire (large and small fire)
control, large/small automatic switching according to equipment
load control, meeting high precision load control requirements .
It is widely used in small and medium-sized boilers, heating
furnaces, spraying equipment, drying equipment, heat treatment
equipment and other thermal energy equipment to achieve
applications with certain load control accuracy requirements.
1, Safe and reliable automatic program control
1. Fully automatic program control operation, which can control
large/small fire switching according to load parameter setting to
realize automatic control of output force;
2. The ion-induced or UV-UV monitoring device is used to realize
the accidental flameout protection function to ensure the flame
combustion safety and stability;
3. Configure gas pressure and air pressure safety protection
switch, and at the same time, it can easily realize external
interlock control to ensure safe operation;
2, Good combustion performance
1. The large/small fire state can be freely set within the
processing range, and the load output control is more flexible and
convenient;
2. When the large/small fire is switched, the air volume can be
automatically adjusted according to the setting, ensuring that the
large/small fire state is realized.
Good combustion state;
3, Flexible configuration
1. The proportional control of small and medium-sized burners can
be realized by adding a proportional proportional adjustment device
to meet the requirements of higher precision load control;
2. It can be adapted to different origin supply modes by increasing
the configuration of gas pressure regulating and filtering devices;
Natural gas burner for boiler will supply u highest buying experience :
1. CE standard ,comply with 90/396/EEC;PIN63AP6680
2. EMC comply with 89/336/EEC
3. Burner comply IP40,EN60529 protection
4. Burner gas valve comply with EN676
5. Two-stage operation (high/low flame).
6. Compatible with any type of combustion chamber, according to
EN303 standard
7. High blowing efficiency, low electrical input, low noise.
8. Air-gas mixing at blast-pipe.
9. Maintenance facilitated by the fact that the mixing unit can be
removed without having to remove the burner from the boiler.
Natural gas burner for boiler with famous part ,long life time:
SIEMENS CONTROLLER
DUNGS VALVE
DANFOSS NOZZLE
SUNTEC OIL PUMP
BRAHMA/PARKER SOLENOID VALVE
FIDA TRANSFERMA
SIEMENS SERVOMOTOR
Natural gas burner for boiler DATASHEET FOR REFERENCE
NATRUAL GAS BURNER EMAIL: bettysun001@vip.126.com | |||||||
MODEL | GAS COMBUSTION | BURNER OUTPUT | MAIN SUPPLY | Motor | CONTROL METHOD | ||
NM3/HR | KW | ||||||
MIN | MAX | MIN | MAX | KW | |||
SINGLE STAGE CONTROL | |||||||
YXG5 | 3 | 5.7 | 30.06 | 56.3 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG6 | 3 | 5.7 | 30.06 | 56.3 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG11 | 4.8 | 10 | 48.8 | 99 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG10 | 4.8 | 99 | 48.8 | 99 | 1N-220V 50HZ | 0.15 | ONE STAGE |
YXG17 | 7 | 17 | 69 | 169 | 1N-220V 50HZ | 0.15 | ONE STAGE |
YXG20 | 5.85 | 20.1 | 80 | 200 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG30 | 6 | 30 | 60 | 300 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG35 | 9 | 35.8 | 90 | 359 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG34 | 12 | 38 | 118 | 338 | 3N-380V 50HZ | 0.37 | ONE STAGE |
YXG40 | 19 | 43 | 185 | 425 | 3N-380V 50HZ | 0.55 | ONE STAGE |
YXG50 | 17 | 60 | 169 | 586 | 3N-380V 50HZ | 0.55 | ONE STAGE |
TWO STAGE CONTROL | |||||||
YXG20P | 5.85 | 20.1 | 80 | 200 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG30P | 6 | 30 | 60 | 300 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG35P | 9 | 35.8 | 90 | 358 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG34P | 12 | 38 | 118 | 338 | 3N-380V 50HZ | 0.37 | TWO STAGE |
YXG40P | 19 | 43 | 185 | 425 | 3N-380V 50HZ | 0.55 | TWO STAGE |
YXG50P | 17 | 60 | 169 | 586 | 3N-380V 50HZ | 1.5 | TWO STAGE |
YXG60P | 25 | 75 | 248 | 738 | 3N-380V 50HZ | 1.5 | TWO STAGE |
YXG100P | 28 | 101 | 280 | 995 | 3N-380V 50HZ | 2.2 | TWO STAGE |
YXG120P | 35 | 121 | 350 | 1200 | 3N-380V 50HZ | 2.2 | TWO STAGE |
YXG150P | 42 | 144 | 414 | 1428 | 3N-380V 50HZ | 3 | TWO STAGE |
YXG200P | 60 | 202 | 590 | 2000 | 3N-380V 50HZ | 3 | TWO STAGE |
YXG250P | 50 | 253 | 490 | 2500 | 3N-380V 50HZ | 7.5 | TWO STAGE |
YXG300P | 66 | 313 | 657 | 3100 | 3N-380V 50HZ | 7.5 | TWO STAGE |
YXG350P | 93 | 350 | 924 | 3500 | 3N-380V 50HZ | 9 | TWO STAGE |
BQ SEARIES
YONGXING BOILER GROUP CO.,LTD ------Bonarate burner sales@yxboiler-factory.com | |||||||
BQ SERIES GAS BURNER | |||||||
Burner model | Suitable for boiler (TON/H) | Burner thermal power (KW) | Burner thermal power (CAL/H) | Gas Consume (NM3/H) | Fan power (KW) | Applicable fuel | Adjust Method |
BQ6 | 1 | 175-940 | 151,000-808,000 | 17.5-94 | 1.5 | CITY GAS, NATURAL GAS, LPG GAS gas heat value 36Mj/M3 | Z-Sliding two stage R-Mechanical ratio control E-Electronic proportional control |
BQ10 | 1.5 | 300-1750 | 258,000-1,505,000 | 30-175 | 3 | ||
BQ15 | 2 | 400-2250 | 344,000-1,935,000 | 40-225 | 4 | ||
BQ20 | 3 | 500-3500 | 430,000-3,010,000 | 50-350 | 7.5 | ||
BQ30 | 4 | 500-4080 | 430,000-3,509,000 | 50-408 | 10 | ||
BQ35 | 5 | 900-4780 | 774,000-4,110,000 | 90-478 | 12 | ||
BQ40 | 6 | 700-5400 | 602,000-4,644,000 | 70-540 | 13.5 | ||
BQ55 | 8 | 1000-8150 | 860,000-7,009,000 | 100-815 | 15 | ||
BQ70 | 10 | 1000-10500 | 860,000-9,030,000 | 100-1050 | 22 |
We need to ask you some details for sending you the more suitable quotation
1. what is the application of the burner ?(for food industry
,textile industry, chemical industry or others )
2. what is the capacity per hour do you need?(how many kw ?)
3. which fuel do you want to use for your boiler?(oil or
gas,lpg,kerosene and etc ?)
Pls send us effiicent info to get the price soonest.