Strain Gauge Load Cell, S type, 5kg/50kg/1000kg/3 ton to 20 ton
Tension and compression load cells have capacity range from 5kg,
50kg, 300kg, 1000kg, 3 ton to 20 ton. Strain gauge load cell
capacity can be customized according to customer requirements.
After purchasing one RJ load cell, you can buy a special digital
panel meter to obtain readings directly, or buy a transmitter to
output standard signal to PLC, DCS and other systems. Customized
output signal is 0-5V, 0-10V, or 4-20mA.
Specification:
Model | RJ-LCS-TJL-1 |
Shipping weight | 2~15kg |
Capacity range * | 5 kg~20 ton |
Matched Display Controller | RJ |
Accuracy | 0.02~0.03%F.S (linearity + hysteresis + repeatability) |
Sensitivity | 2.0±0.1mV/V |
Creep | ±0.02~±0.03%F.S/30min |
Zero output | ±1%F.S |
Temperature effect on zero | ±0.02~±0.03%F.S/10℃ |
Temperature effect on output | ±0.02~±0.03%F.S/10℃ |
Operating temperature | -20℃~+65℃ |
Input impedance | 380±10Ω |
Output impedance | 350±3Ω |
Insulation resistance | ≥5000MΩ |
Safety overload | 150%F.S |
Bridge voltage (excitation voltage) | DC 10V |
Material | Alloy steel (Stainless steel load cell can be customizable, contact us for further communication. MOQ: 5pcs) |
Protection class | IP67 (except 5 kg model) |
Cable length | 3m (<5 ton), 6m (≥5 ton) |
Wiring | EXC+: Red, EXC-: Black, SIG+: Green, SIG-: White |
Accessories * | A pair of rings (only for capacity≤1000kg) |
Dimension:
Capacity | Dimension (mm) | |||
A | B | C | M | |
5~50kg | 64 | 51 | 12.7 | M8 |
100~700kg | 76 | 51 | 19.1 | M12 |
1~1.5 ton | 76 | 51 | 25.4 | M12 |
2~5 ton | 108 | 76 | 25.4 | M20 |
7.5~10 ton | 178 | 127 | 51 | M30 |
20 ton | 188 | 140 | 60 | M36*3 |
Tips: How to select load cells?
The selection of the load cell quantity is decided according to the
application of the electronic weighing instrument, the number of
points required to be supported of the scale (the number of points
should be determined according to the principle that the geometric
gravity center of the scale should coincide with the practical
gravity center). Generally, the quantity of the supporting points
is exactly the quantity of the load cell. However, as to some
special scales, such as the electronic crane scale, only one sensor
will be employed. Some electronic-mechanical scales should be
decided of the load cell quantity according to the practical
conditions.
The selection of the load cell range can be determined according to
the comprehensive assessment of the maximum weighing value of the
scale, the quantity of the load cell, the dead weight of the scale,
the possible generated maximum eccentric load, dynamic load and
other factors. Generally, if the measuring range of the load cell
is close to the load distributed to each sensor, the weighing
accuracy is high. However, in the practical operation, because the
load exerted to the sensor still includes the scale dead weight,
tare weight, eccentric load and vibratory impulse and so on in
addition to the weighed products, factors of several aspects should
be considered in selecting the load cell range, so as to ensure the
safety and service life of the load cell.
Company Information
Q1:How do you control the quality?
A:We have QC team comply with TQM,each step is in compliance to the
standards.At the same time,they will take photos and shoot video
for you.
Q2: Can you print our brand on the product?
A: Yes, Of course. It can make customer's brand logo.
Q3: What is the payment terms?
A: T/T,L/C,etc.
Q4: How long is your warranty period?
A: Our warranty period is 12 months.