Add to Cart
100%VOL CH4 Methane Purity Combustible Gas Detector IR Sensor Alarm
and Display
Functions:
1. Monitor the CH4 Methane gas in environment or pipeline.
2. With self-calibration and zero calibration function, makes the
detection more accurate and reliable.
3. With temperature compensation, this is able to realize gas
concentration compensation under conditions of different
temperatures.
4. Infrared ray controller can remote control alarm point settings,
zero calibration, and address modification. (optional)
5. Can output one or two on-off signals, can drive ventilator or
solenoid valve and other external devices. (optional)
6. Working Voltage:24V DC
7. Case: die-cast aluminum
Technical Parameters:
Gas detected | CH4 Methane | ||
Detection principle | IR, Catalytic Combustion | ||
Install method | Wall-mounted, piping type, flow-type (according to the detected environment) | ||
Measure range | 0-10000ppm, 0-5%VOL, 0-100%VOL, 0-100%LEL | ||
Resolution | 1ppm, 0.01%VOL, 1%LEL | ||
Precision | ≤± 1-2% FS | ||
Signal output | 4-20mA, 0-5V, RS485, relay(optional) | ||
Response time | ≤10S | Recovery time | ≤10S |
Repeatability | ≤±1% | Linearity error | ≤±1% |
Zero shift | ≤±1%(FS/year) | Display | High-light nixie tube display |
Connection mode | G1/2 external thread explosion-proof flexible pipe | Unit | ppm |
Temperature | -20 to 50°C | Humidity | 0-95%RH |
Explosion-proof | Ex dⅡCT6 | Degree of protection | IP65 |
Alarm | Sound, light | Operating time | 24H |
Dimensions | 180*150*90mm | Weight | ≤2kg |
Characteristics:
1. Standard equipped with three-wire system 4-20mA analog output;
relay output; RS485 output.
2. Unique infrared ray control function, which can non-contacted
control the device.
3. Being compatible with all kinds of controlled alarms, PLC, DCS
and other control system, can be remote monitored.
4. Alarm mode is sound and light, alarm point is settable.
5. Explosion-proof design, fast, reliable and stable.
6. Explosion-proof grade: Ex dⅡCT6
7. With self-calibration function, and three standard keys will be
used to realize on-site maintenance.
8. Detachable probe/gas cell: It is very easy to calibrate and replace sensor
FAQ:
Q1. Can it applied to other gases?
A: YT-95H series can detect a wide range of gases, but one device
is designed for one gas.
Q2. What is your minium order?
A: Sample order of 1 set for chacking quality is welcome
Q3. What about the lead time?
A: We usually deliver the goods in 2-5 working days after the order
confirmed.
Q4. How is the calibration been done?
A: To keep the high sensitivity, please calibrate it at least once
a year .
Q5. Is it OK to print my logo on the gas detector?
A: Yes. Please inform us formally before our production and confirm
the design firstly based on our sample.
Q6. How to contact us?
A: Please send your enquiry to us, we will reply you without delay.