Refrigerant Sensor Detector R125 R134A HFC125 Gas Analyzer IR Sensor High Quality Detector
SKY2000 series gas detector is a kind of fast response and high accuracy gas measurement device. With internal sampling pump, fast sampling speed and high flow rate, ensuring the response time of the detector. Unique design, small size and easy to carry with. Special high intensity engineering plastics housing, suitable for different kinds of situation and environment. We dedicate to provide you the most reliable, accurate and the safest solution of gas detection.
Gas Detected | R125 R134A HFC125 | ||
Detection principle | IR | ||
Sampling Method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. | ||
Measure Range | 0-1000,2000ppm | ||
Resolution | 1ppm | ||
Precision | ≤± 2% F.S. | ||
Signal Output | High-speed data transmission by USB, available for data downloading and printing(optional function) | ||
Response Time | ≤10S | Recovery Time | ≤10S |
Repeatability | ≤±1% | Linearity error | ≤±1% |
Zero shift | ≤±1%(F.S/year) | Display | LCD dot matrix display |
Operating language | Chinese/English | Gas unit | Units are switchable |
Temperature | -40℃~70℃ | Humidity | 0-95%RH |
Explosion-Proof | ExiaⅡCT4 | Degree of protection | IP66 |
Alarm mode | Sound, light, vibration | Operating time | 100h(pump off) |
Dimensions | 205*75*32mm | Weight | 300g |
Characteristics & Functions
1) Adjustable low and high alarm level
2) Adjustable calibrating level
3) High concentration protection for combustible gas
4) Self test for the combustible gas sensor
5) Low battery indication
6) Replaceable sensor module
7) Self-adjustment function
8) Visual and audible alarm with vibration
9) Advanced self-examination and self-renovation function
10) Password management to avoid wrong operation
11) Explosive proof housing
Precautions
1. Must open the device in clean air
2. It is strictly forbidden to open the cover and use the instrument on site
3. It is strictly forbidden to replace the sensor with power on
4. Installation, debugging, setting and other operations must be carried out by professionals
5. The calibration check should be carried out regularly, and the sensors that have exceeded the valid period of use and have faults should be replaced in time
6. It is strictly forbidden to shock the sensor with gas higher than the measuring range
7. Prevent the instrument from falling from a high place or subject to severe shocks
8. It is strictly forbidden to expose the instrument to a high-concentration corrosive gas environment to work for a long time to prevent damage to the sensor
FAQ
Q1. How can I get the sample to check your quality?
After price confirmation, you can require for samples to check our product’s quality.
Q2. What can I get the price?
We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please just call us we will regard your inquiry priority.
Q3. What is your term of delivery?
We accept EXW, DAP, FOB Shenzhen. You can choose the best convenient or cost effective way for you.
Q4. What about the lead time for the mass production?
Honestly, it depends on the order quantity and the season you place the order.