Add to Cart
Description
The 3500/45 Position Monitor is a 4-channel instrument that accepts
input from proximity transducers, Rotary Position Transducers
(RPTs), DC Linear Variable Differential Transformers (DC LVDTs), AC
Linear Variable Differential Transformers (AC LVDTs), and rotary
potentiometers. The monitor conditions the input and compares the
conditioned signals with user-programmable alarms.
The type of measurement and transducer input determine which I/O
modules are required. See Transducer Types for Position
Measurements on page 10., See Figures and Graphs on page 12., and
See I/O Modules for AC LVDTs and Rotary Potentimeters on page 14.
You can program each channel using the 3500 Rack Configuration
Software to perform the following functions:
Axial (thrust) Position
Differential Expansion
Standard Single Ramp Differential Expansion
Non-standard Single Ramp Differential Expansion
Dual Ramp Differential Expansion
Complementary Differential Expansion
Case Expansion
Valve Position
The monitor channels are programmed in pairs and can perform up to two of these functions at a time. For example, Channels 1 and 2 can perform one function while channels 3 and 4 may perform the same or a different function.
The primary purpose of the 3500/45 Position Monitor is to provide
the following:
Machinery protection by continuously comparing monitored parameters
against configured alarm setpoints to drive alarms
Essential machine information for operations and maintenance personnel
Each channel, depending on configuration, typically conditions its input signal to generate various parameters called measured variables. You can establish alert setpoints for each active measured variable and danger setpoints for any two of the active measured variables.
Ordering Information
For the detailed listing of country and product specific approvals,
refer to the Approvals Quick Reference Guide (108M1756) available
from Bently.com.
Position Monitor3500/45-AA-BB
A: I/O Module Type
01 Position I/O Module with Internal Terminations (Proximitor, RPT,
DC LVDT)
02 Position I/O Module with External Terminations (Proximitor, RPT,
DC LVDT)
03 Discrete TMR Position I/O Module with External Terminations
(Proximitor or DC LVDT)
04 Bussed TMR Position I/O Module with External Terminations
(Proximitor)
05 AC LVDT Position I/O Module with Internal Terminations
06 AC LVDT Position I/O Module with External Terminations
07 Rotary Potentiometer Position I/O Module with Internal
Terminations
08 Rotary Potentiometer Position I/O Module with External
Terminations
B: Agency Approval
00 None
01 CSA / NRTL / C (Class 1, Division 2)
02 ATEX / IECEx / CSA (Class 1, Zone 2)
You must order external termination blocks and cables separately for each I/O module with external termination.
When using the 3500/45 Position Monitor in a TMR application, valve position measurement are not available, and case expansion measurements are only supported for Discrete TMR.
Spares
176449-04 3500/45 Position Monitor
135137-01 Position I/O Module with Internal Terminations for use
with Proximitors, RPTs or DC LVDTs
135145-01 Position I/O Module with External Terminations for use
with Proximitors, RPTs or DC LVDTs
139554-01 AC LVDT Position I/O Module with Internal Terminations
for use with AC LVDTs
3300/16-15-01-03-00-00 3300/16-15-01-03-00-00-00 |
3300/20-12-01-00-00-00 3300/20-12-01-01-00-02-00 3300/20-12-01-03-00 |
3300/52-02-00-00 |
3300/53-03-02 |
3300/55-03-01-15-15-00-00-01-00 3300/55-03-04-15-15-00-00-05-00 |
3300/65-14-01-00-00-01 |
126648-01 KEYPHASOR I/O MODULE |
128229-01 Proximitor Seismic I/O Module |
133323-01 TACHOMETER MODULE |
133396-01 OVERSPEED PROTECTION IO MODULE |
135137-01 Position I/O Module |
135473-01 Barrier Keyphasor I/O Module |