PP Low Pressure Diaphragm Pump Chemistry Industry Membrane Pump Self Priming

Brand Name:BSK
Model Number:BSKP06PP-PTT-B
Minimum Order Quantity:10
Delivery Time:5days
Payment Terms:FOB T/T
Place of Origin:Guangzhou
Contact Now

Add to Cart

Verified Supplier
Location: Foshan Guangdong China
Address: E 18Floor Fazhan Build No.13 Easy Huayuan Road Chancheng Area Foshan City.
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

Low Pressure Polypropylene Diaphragm Pump / Membrane Pump


Air diaphragm pump


(also know as a Membrane pump, air operated double diaphragm pump(AOOD)or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.


ItemDescriptionUnitReference Figure
1Maximum air inlet pressureMpa0.6
2Maximum flow rate1/Min27
3Maximum liftM45
4Maximum outlet pressureMpa0.6
5Maximum particle sizemm1
6Weightkg1.8
7Noise leveldb<68
8Max dry suctionm4.2


Specifications

Air Diaphragm Pump
1. Non leakage
2. Good self priming performance
3. Convey all kinds of medium

Main Advantages
1, Due to the use of air power, the flow automatically changed according to export resistance. Which is suitable for high viscosity fluid.
2, In inflammable and explosive environment, the pump is reliable and low cost, won't produce spark and not overheat,
3, The pump volume is small, easy to move, no foundation needed, convenient installation and economy. Can be used as mobile conveying pump.
4, Where there are dangers, corrosive materials processing, diaphragm pump can be separated completely with outside.
5, The pump shearing force is low, physical effect to medium is small, can be used for conveying unstable chemistry fluid.



FLUID SECTION DISASSEMBLY

  • Remove the upper and lower manifold (1) and (11).
  • Remove the ball (2), “O” ring (3) (47) and ball seat (4).
  • Remove the fluid cap (5).

NOTE: Only diaphragm models use a primary diaphragm(6A) and a backup diaphragm(6). Refer to the aux iliary view in the Fluid Section illustration.

  • Remove the screw (10), washer (9), diaphragm (6A, 6) and diaphragm washer (7, 8).
    NOTE: Do not scratch or mar the surface of (23) diaphragm rod.

FLUID SECTION REASSEMBLY

  • Reassemble in reverse order.
  • Clean and inspect all parts. Replace worn or damaged parts with new parts as required.
  • Lubricate (23) diaphragm rod and 25) “Y” ring with grease.
  • Fix the diaphragm rod (23) with the auxiliary installation tool.
  • Prior to the final fastening of bolts and nuts, please determine whether the diaphragm (6A,6) is aligned with the fluid cap (5) properly to avoid the twisting of the diaphragm.
  • For the models using diaphragm: three rubber diaphragms (6) on the side, which are marked with AIRS SIDE "air chamber" are mounted in face of the pump body.
  • Start the pump, check the fastening and sealing after it runs for a period of time.