BW-AID thermal protector,BW-AID thermal protector for fan motor
BW series thermostat / KSD9700 thermal protector / BW9700 temperature protector
1. BW series thermostat’s Principle and structure
BW serial universal and enhanced protectors with large metal casing
are composed of the thermal conductive metal casing, bimetallic
parts welded with silver alloy contact point, conductive bracket,
insulation fixation stand, fixed contact strip and heat resistance
cable. In case of abnormal operation, along with the increase of
the environment temperature to the set value, the bimetallic parts
perform quick action, open the contact point, and disconnect the
circuit. When the device is cooled to the temperature for safe
operation, the contact point will automatically closes and recover
normal operation.
2. BW series thermal protector’s Specification
2.1. Switch type: normally closed, normally opened.
2.2. Operating Voltage / Current: AC250V / 5A; AC125V / 8A
2.3. Operating Temperature: 40~150℃ (one step for every 5°C)
2.4. Standard Tolerance: +-3°C / +-5°C / +-7°C
2.5. Reset temperature: operating temperature decrease by 15-45°C
2.6. Contact Closure resistance: ≤50mΩ
2.7. Insulation resistance: ≥100mΩ
2.8. Electric strength: AC1500V/1min free from phenomena of break down and flashover.
2.9. Service life: 10000 times
3. BW series thermal protector’s Dimension
Model | Length | width | High |
BW9700 | 20 | 7.3 | 3.8 |
4. BW series temperature protector’s Application
BW series is applicable to chargeable battery, ballast, massager,
motor, transformer, electric tools, heat electric appliance and
instrument etc.
Code | Open temperature | Reset temperature | Code | Open Temperature | Reset Temperature |
045 | 45+-4.5℃ | ≥33℃ | 105 | 105+-5℃ | 75+-15℃ |
050 | 50+-5℃ | ≥35℃ | 110 | 110+-5℃ | 75+-15℃ |
055 | 55+-5℃ | 42+-6℃ | 115 | 115+-5℃ | 80+-15℃ |
060 | 60+-5℃ | 45+-8℃ | 120 | 120+-5℃ | 85+-15℃ |
065 | 65+-5℃ | 48+-10℃ | 125 | 125+-5℃ | 85+-15℃ |
070 | 70+-5℃ | 50+-12℃ | 130 | 130+-5℃ | 90+-15℃ |
075 | 75+-5℃ | 53+-14℃ | 135 | 135+-5℃ | 95+-15℃ |
080 | 80+-5℃ | 55+-15℃ | 140 | 140+-5℃ | 100+-15℃ |
085 | 85+-5℃ | 60+-15℃ | 145 | 145+-5℃ | 100+-15℃ |
090 | 90+-5℃ | 65+-15℃ | 150 | 150+-5℃ | 105+-15℃ |
095 | 95+-5℃ | 70+-15℃ | 155 | 155+-5℃ | 110+-15℃ |
100 | 100+-5℃ | 70+-15℃ |
The product UL,CQC,VDE and RoHS certification approval.