Add to Cart
LW31 series Rotary Changeover Switch Cam Switch
Description:
LW31 series Rotary Changeover Switches applied to Complete
electrical switchgear and Three-phase asynchronous motor load start
shift steering; For using as main circuit and auxiliary circuit
conversion. It’s a good substitution for other cam switches
Advantage:
Technical parameters
Description | LW31-20 | LW31-25 | LW31-32 | LW31-50 | LW31-75 | |||||||||||||||||||
Rated thermal currentITH | A | 20 | 25 | 32 | 50 | 75 | ||||||||||||||||||
Rated working voltageUe | V | 110 | 220 | 440 | 110 | 220 | 440 | 500 | 690 | 110 | 220 | 440 | 500 | 690 | 110 | 220 | 440 | 500 | 690 | 110 | 220 | 440 | 500 | 690 |
Rated working currentLe | ||||||||||||||||||||||||
AC-21A | A | 20 | 25 | 32 | 50 | 70 | ||||||||||||||||||
AC-22A | A | 16 | 20 | 32 | 40 | 63 | ||||||||||||||||||
DC-20 | A | 20 | 25 | 32 | 50 | 75 | ||||||||||||||||||
power | P | |||||||||||||||||||||||
AC-23A | KW | 5 | 7.5 | 7.5 | 11 | 15 | 11 | 18.5 | 22 | 15 | 22 | 30 | 18.5 | 30 | 37 | |||||||||
AC-3 | KW | 4 | 5.5 | 5.5 | 7.5 | 11 | 7.5 | 15 | 18.5 | 11 | 18.5 | 22 | 15 | 22 | 30 | |||||||||
AC-4 | KW | 2.2 | 3 | 2.2 | 4 | 4 | 3 | 5.5 | 5.5 | 5.5 | 7.5 | 9 | 7.5 | 11 | 15 | |||||||||
DC-23 | KW | 0.77 | 1.2 | 2 | 2.2 | 2 | 2.2 | 3 | 6 | 4 | 8 |
Mechaical life
Mechanical life without load:0.3×106 times,operation frequency is 120 times/h.
Mechanical life with load:0.6×104 times operation frequency is 120 times/h.
Description | Dimensions(mm) | Installation(mm) | ||||||||||
A | C | H | L | E | D1 | D2 | S | F | G | D3 | T | |
LW31-20 | □54 | Φ44 | 38 | 25+12n | 32 | Φ9.5 | Φ3.2 | 1.5 | 35 | Φ45 | Φ4.5 | 6 |
LW31-20 | □72 | Φ44 | 38 | 25+12n | 32 | Φ9.5 | Φ3.2 | 1.5 | 58 | Φ45 | Φ4.5 | 6 |
LW31-25 | □72 | Φ59 | 36 | 25+13n | 33 | Φ9.5 | Φ3.2 | 1.5 | 58 | Φ64 | Φ4.5 | 6 |
LW31-25 | □105 | Φ59 | 53 | 23+13n | 33 | Φ9.5 | Φ3.2 | 1.5 | 85 | Φ64 | Φ4.5 | 6 |
LW31-32 | □72 | Φ59 | 36 | 23+18n | 33 | Φ9.5 | Φ3.2 | 1.5 | 58 | Φ64 | Φ4.5 | 6 |
LW31-32 | □105 | Φ59 | 53 | 23+18n | 33 | Φ9.5 | Φ3.2 | 1.5 | 85 | Φ64 | Φ4.5 | 6 |
LW31-50 | □105 | Φ80 | 53 | 34+18n | 46 | Φ13 | Φ5.3 | 3 | 85 | Φ90 | Φ5.5 | 8 |
LW31-75 | □105 | Φ80 | 53 | 34+27n | 46 | Φ13 | Φ5.3 | 3 | 85 | Φ90 | Φ5.5 | 8 |
Normal working conditions:
1. Working temperature: -25°C~+40°C;the average temperature mustn’t be pass 35°C
2. Working height: ≤2,000m
3. Relative humidity: ≤50% with highest temperature +40°C,but allow higher humidity with low temperature less than 40°C.(eg. humidity 90%----teperature20°C)