3 Position 180 Degree Pneumatic Actuator / Double Acting Valve Actuator Fine Tightness

Brand Name:Veson/OEM
Certification:ISO/CE/SIL3
Model Number:VS-092DA-180°
Minimum Order Quantity:1 Ea
Delivery Time:One week
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

Pneumatic Actuator - 180 Degree Rotary Actuator


pneumatic actuator used, make sure the valve opens, closing torque, and then do the valve using a fluid medium, added security value. For cleaning, lubricating medium increased by 20% Security value; of water vapor and non-lubricating medium security value by 25%; non-lubricated dry gas media to increase 60% security value; non-lubricated gas transmission medium to increase the powder particles 100% security value. Then the gas supply pressure of work, find the double-action or single-acting output torque table, available and accurate actuator signal. Single-acting torque Table, the minimum time to close the valve spring torque is the torque, maximum torque is to open the valve spring torque.


Two additional pistons make a third (intermediate) position possible. The intermediate position is exactly reproducible. To use for multiple-way valves and pig valves. Safety function with spring-centered central position


pneumatic twin piston actuator, single-acting and double-acting version with two additional pistons, pivoting angle 90°+ 90° (180°) respectively 120°+ 120° (240°)

valve combinations (preferably 3/2-way) corresponding safety conception respectively requirements.


Installation and maintenance


1, the pneumatic actuator can be directly connected with the valve, brackets and fittings can also be connected with the valve installation. Fasteners must not loose connection.


2, to ensure that the actuator output shaft coaxial with the valve stem is installed, and turn the flexible non-crawling phenomenon.


3, connecting pipes, fittings, accessories, etc. should be clean.


4, solenoid valve scheduled port is always down, when the level up or when the pipe should be connected so that the exhaust downward.


5, testing should be determined before the channel clear air, pressure, voltage, signals meet the requirements.


6, compressed air should be filtered, dried, dew point -15 ℃ to dehumidify the following.


7, solenoid valve should open when debugging to the automatic position.


8, pneumatic operation, the device should be disconnected manually, manually operated pneumatic devices should be disconnected.


9, the actuator is installed on a variety of accessories, should be separately described with reference to use for debugging,


10, under normal operating conditions once a month, once a year overhaul.

Parameter

Description

TypeVeson 3 Position Pneumatic Actuator
Number of Positions3 (Open, Closed, Intermediate) 0-45-90 or 0-90-180 or others
Actuation MethodPneumatic pressure
Actuator ConfigurationSingle-acting or double-acting
Operating PrincipleAir pressure applied to move the actuator's piston
Position SensingLimit switches or position sensors for feedback
Control SignalPneumatic signal (typically air pressure or vacuum)
Actuator BodyRigid and durable construction (e.g., metal or alloy)
Seal TypeO-rings or other suitable sealing materials
Pressure RangeVaries based on application requirements
Fluid CompatibilityCompatible with compressed air or other gases
Mounting OptionsVarious mounting options (e.g., flange, clevis)
MaintenancePeriodic inspection and lubrication as required
ApplicationUsed in various industries for valve or damper control

China 3 Position  180 Degree Pneumatic Actuator / Double Acting Valve Actuator  Fine Tightness supplier

3 Position 180 Degree Pneumatic Actuator / Double Acting Valve Actuator Fine Tightness

Inquiry Cart 0