Emergency Shutdown Valve Quarter-Turn Operation Close Valve In Less Than A Second


ESDV features are designed for accuracy and dependability


■ Trunnion-mounted ball valve
■ Fail-safe spring return actuator
■ Low emissions design
■ Anti-blowout stem configuration
■ Fast response time

Full Open Position – Normal Operation
The ESDV provides minimal pressure Differential when Differential when the valve the valve is in full-open-open position.
The full bore ball valve virtually acts like a pipe minimizing process fluid turbulence

Full Closed Position – Emergency Situation

Setpoint pressure has been exceeded and the ESDV the ESDV has fully closed providing fully closed providing tight shutoff with its double-seated design.

■ Valve Type: Trunnion mounted full port ball valve
■ Body Style: Side entry, forged body
■ Actuator Type: Single-acting, spring return
■ Instrumentation: Pneumatic
■ Size Range: 6 – 36”
■ Pressure Ratings: ANSI Class 150 - 2500
■ Shut Off: Soft seat - tested up to Class VI Metal seat - tested up to Class V
■ End Connections: RFFE, RTJ, weld end
■ Closing Time < 2 second (depending on size

Operation Step

Emergency Shutdown Valve Quarter-Turn Operation to Close the Valve Action

Step 1Verify the availability of power supply and ensure it is turned on.
Step 2Identify the emergency shutdown valve to be closed.
Step 3Position yourself in a safe location away from the valve.
Step 4Locate the manual or automatic control mechanism for the valve.
Step 5If using a manual control mechanism, turn the handle or lever clockwise to close the valve.
Step 6If using an automatic control mechanism, initiate the shutdown sequence according to the manufacturer's instructions.
Step 7Monitor the valve's position indicator to ensure it is fully closed.
Step 8Confirm the valve's closure by checking the pressure or flow indicators associated with the valve.
Step 9Secure the valve by engaging any locking mechanisms, if applicable.
Step 10Notify the appropriate personnel or control room about the closure of the emergency shutdown valve.