CE Procise Plasma Wand Spine Probe Minimally Invasive Plasma Surgery

Brand Name:MECHAN
Certification:CE, ISO13485
Model Number:PLA301
Minimum Order Quantity:Negotiation
Payment Terms:T/T, L/C
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Chengdu Sichuan China
Address: No. 11, District 9, Huayin Industrial Harbor, No. 618, West Kelin Road, Chengdu Straits Science & Tech Industrial Development Park, Wenjiang District, Chengdu city, Sichuan Province, China. 611130
Supplier`s last login times: within 21 hours
Product Details Company Profile
Product Details

Procise Plasma Wand Spine Probe Minimally Invasive Plasma Surgery


Product Introduction


MECHAN Orthoepedic Plasma Surgery System PLA-800 are designed to operate in urology field, it includes both ablation and coagulation modes, which result in different tissue effects. It is widely applying to spine and joints treatment.


Product Diagram



Product Character


• Establishes a plasma layer quickly and efficiently
• Maintains a stable and aggressive plasma layer
• Maximizes the size of the plasma layer

Technical Parameter


Input Volts

198-240V 50Hz

100-120V 60Hz

Export device could convert automatically per customer requirements

Output Power

Ablation or resection: ≤351W

Coagulation or hemostasis: ≤111W

Working Frequency100 KHz ± 10%
Dimension405*440*130mm (L*W*H)
Working Mode

Ablation and resection: level 1-10

Coagulation: level 1-10

Weight7.0kg

Product Advanatages


  • Safety: multi-polar design, change the traditional way that current flow through human body
  • Low Temperature: 40 to 70 centigrade during operation, decrease the thermal damage to around normal tissue
  • Precise cutting: the thin plasma layer make precise cutting becoming true, and it will not hurt the around normal tissue
  • Speedy cutting: cutting and coagulation at the same time, no need to change the probe frequently, saving operation time
  • Shorten recovery period: less hurt to human body, recovery faster

System Set Up


1). One tabletop generator device

2). One reusable and non-sterile power supply cable.

3). One reusable and non-sterile footswitch.

4). One reusable and non-sterile treatment handle which is for foot control.

5). Treatment probes.


DescriptionRemark
Manufacturer LogoMECHEN Brand.
PadsInsulation and support on the surface.
Receptacle of FootswitchConnects with Footswitch which determines ablation or coagulation mode.
Receptacle of Treatment HandleConnects with the treatment accessories.
Power SwitchSystem start power button. “O” means power off; “I” means power on.
ABLATION mode SelectorSelect ABLATION mode 1 or 2 Output waveform.
Indicator of Treatment Probe ConnectionLED turns on green when the probe cable is connected and turns on red when it is not connected.
Indicator of Footswitch ConnectionLED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
ABLATION Power Setting Display

Shows the preset ABLATION output value in two digits.

“01” with Min. power output, and “10” with the highest output.

Ablation Output Power Up/Down ButtonThe number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

Anesthesia


Epidural anesthesia is usually used. You can also choose spinal anesthesia or general anesthesia.


Storage Condition


This device should be stored in a well-ventilated room without corrosive gas. The height above ground and the distance from wall should be above 30cm. Stack limit is 6 cases. Before being stored for a long time, it should be cleaned thoroughly for proper packing and storage. And it should also be taken out for power up every year, in order to avoid it from moisture, mildew or even damage. The suitable weather and environment condition is as below:

1. Temperature: -40℃~+55℃;

2. Relative humidity: ≤90%;

3. Atmospheric pressure: 50kPa~106kPa