RF Plasma Coblator Ⅱ Bipolar Electrode For Hip/Knee Repair-Ligament/Meniscus

Brand Name:MECHAN
Certification:CE, ISO 13485
Model Number:PLA-800
Minimum Order Quantity:1
Delivery Time:5-8 work days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Chengdu Sichuan China
Address: No. 11, District 9, Huayin Industrial Harbor, No. 618, West Kelin Road, Chengdu Straits Science & Tech Industrial Development Park, Wenjiang District, Chengdu city, Sichuan Province, China. 611130
Supplier`s last login times: within 21 hours
Product Details Company Profile
Product Details

RF Plasma Coblator Ⅱ Bipolar Electrode For Hip/Knee Repair-Ligament/Meniscus

Mechan 01 Product Components


The Mechan RF Plasma Generator includs a pair of footswitch, power cable.


Item 1: RF Plasma Generator




We design and manufacture technology that takes the limits off living. We support healthcare professionals to return their patients to health and mobility, helping them to perform at their fullest potential.


New technology RF devices incorporating a plasma bubble may generate lower intra-articular temperatures and be more efficient.
Compared to standard bipolar radiofrequency technology, the PLA-800 RF Plasma Generator Technology:


• Dissipates rapidly upon contact with tissue
• Provides controlled depth of tissue penetration as well as minimal thermal effect
• No electricity is being delivered to any patient tissue

• More stable energy

• Fewer bubbles

• Lower temperature

• Significantly minimized clogging


Place of Origin:Sichuan, China
Brand Name:MECHAN
Model Number:PLA-800
Technology:RF Plasma Generator
Feature:Cool technology, minimally invasive, less bleeding
Instrument classification:

Class II


Item 2: Footswict of RF Plasma Generator



Item 3: Power Cable



For different countries, we have different Voltage option.


Item 4: Bipolar Electrode



For different requirements we provide different bipolar electrode models.


Mechan 02 Advantages


1. Compared with traditional surgical methods (like electrosurgery and laser), there is no electric current passes through human body, and temperature at the working surface is only 40 – 70 ℃, the thermal injury to adjacent tissue is less. When using the recommended energy levels, the ablation and coagulation depths are controlled at ≤50μm.


2. In coagulation, the low temperature plasma can control the temperature to 40 – 70 ℃ precisely, which not only ensures the shrinking of helical structure of collagen molecule but also maintains vitality of cells.


3. Compared with traditional surgical methods (like electrosurgery and laser), plasma has less thermal energy, lighter thermal injury, shorter wound healing time, and slimmer chance of wound bleeding and scar.


4. Compared with traditional surgical methods (like electrosurgery and laser), intraoperative pain of patient has decreased obviously, and the post-operation inflammatory rate decreased significantly. During surgery, surgeon can stop bleeding at the same time of resection without using any other tool for assistant.


5.Compared with traditional surgical methods (like electrosurgery and laser), PLA -800 is featured with less blood loss, lighter aching feeling, better therapeutic effect,quicker recovery.


Mechan 03 Exhibition And Training


During the past 20 years,we attend many Comprehensive international exhibitions and specialized academic conferences such as Arab Health, Medica, FIME, CMEF, IFOS,AAOS etc. Besides, we also provide online&offline product training courses for distributors and doctors whenever they need.



Mechan 04 Supply Ability


Supply Ability: 10000 Sets per Year



Mechan 05 Packaging & Delivery


Packaging Details: Carton packaging
Port: Chengdu
Lead Time:

Quantity(Sets)1 - 10>10
Est. Time(days)3To be negotiated

Mechan 06 Certifications


Mechan 06 Workshop Display



Mechan 07 Why Choose Us?


  • Professional products and services

---20 years’ independent research and development experience

---High standard production and inspection process

---Excellent after-sales service

  • Advanced technology

---Research pioneer of plasma with the joint efforts of Mechan Medical and the domestic as well as foreign plasma research centers.

---The first enterprise that obtained the CE Certification of Plasma Surgery in China.

---The fourth generation intelligent plasma probe has been successfully developed.

---Mechan has independent intellectual property rights to PLA series surgery system.

  • Extensive Product Range

---Different models of Mechan plasma surgery system can be used in ENT, urology, spinal, arthroscopic, anorectal, ophthalmology surgery and sports medicine.

  • Safe and Reliable

---ISO,CE,FDA,ROHS,EMC Inspection, CMD Audit, Korean KGMP System Audit, Class III Medical Produts of State Food and Drug Administration Approved.

---Mechan products have been exported to more than 20 countries and thousands of hospitals in China use Mechan products.

China RF Plasma Coblator Ⅱ Bipolar Electrode For Hip/Knee Repair-Ligament/Meniscus supplier

RF Plasma Coblator Ⅱ Bipolar Electrode For Hip/Knee Repair-Ligament/Meniscus

Inquiry Cart 0